Skip to main content
CityRuleLookup
Accessory Structures

How Tulsa Handles Accessory Structures: A Practical Guide

By CityRuleLookup Editorial Team

Tulsa maintains 188 local ordinances across all categories, and 5 of those deal specifically with accessory structures. Here is a breakdown of what the city actually requires, what is prohibited, and where Tulsa falls on the strict-to-permissive spectrum compared to other cities.

Shed Rules

Tulsa Zoning Code regulates accessory buildings including sheds under Chapter 45 and the rear setback coverage limits (Table 90-2). A building permit is generally required for sheds. A zoning clearance permit may be needed even when a building permit is not. Setback requirements vary by zoning district (RS-3 requires 5 ft side setback). Maximum building height for accessory structures is 35 feet in most residential districts.

Key details: Permit: Building or zoning clearance required. Setback (RS-3): 5 ft side, varies by district. Max Height: 35 ft in residential districts. Coverage: Per Table 90-2 limits.

Unpermitted structure: retroactive permit with penalty. Non-compliant setback: modification or removal.

Carport Rules

Carports in Tulsa are regulated as accessory buildings under Chapter 45 of the Tulsa Zoning Code (Title 42), with construction governed by Title 51 (Building Code) which adopts the IRC. Building permits are required from Development Services. Detached carports must observe the underlying district setbacks and lot coverage limits; attached carports must meet the principal building setbacks.

Key details: Zoning Authority: Tulsa Zoning Code Title 42 Ch. 45. Building Authority: Tulsa Title 51 Building Code (adopts IRC). Permit Required: Yes - Development Services. Detached Accessory Cap (RE/RS-1): 40% of principal building floor area. Typical Max Height (R districts): Up to 35 ft (district-dependent).

Building or replacing a carport without the required Title 51 building permit, or placing a carport in violation of the underlying zoning district's setbacks or accessory-structure standards in Chapter 45 of Title 42, is a zoning and building code violation enforceable by Tulsa Development Services and the Working in Neighborhoods (WIN) Department through stop-work orders, citations, and orders to remove or relocate the structure.

Tiny Homes

Tulsa permits tiny homes built on a permanent foundation as Accessory Dwelling Units under Chapter 45 of the Tulsa Zoning Code. ADUs are capped at 750 square feet or 40% of the principal home's floor area, whichever is smaller. Construction follows Title 51 (which adopts the IRC, including Appendix Q tiny-house provisions). Tiny homes on wheels are not allowed as primary dwellings in residential districts.

Key details: Authority: Tulsa Zoning Code Title 42 Ch. 45 (ADUs). Building Code: Tulsa Title 51 (adopts IRC + App. Q). Max ADU Size: 750 sq ft or 40% of principal home. Owner-Occupancy: Required (primary or ADU). Infill Overlay: ADUs by-right in RS-3 to RM-3 (Dec 2021).

Constructing a tiny home as a permanent dwelling without the Title 51 building permit, exceeding the 750-square-foot or 40% ADU floor-area cap, locating the unit outside permitted yard areas, or operating an ADU without the owner occupying one of the units violates Chapter 45 of the Tulsa Zoning Code and is enforceable by Tulsa Development Services and Working in Neighborhoods through citations, stop-work orders, and orders to remove or convert the structure. Living in a tiny home on wheels in a standard residential district is a separate zoning violation.

Garage Conversions

Garage conversions in Tulsa require a building permit from Development Services (Title 51, Building Code). The conversion must comply with the adopted 2018 ICC codes for habitable space standards including egress, ventilation, insulation, and electrical. A change of occupancy permit is needed. The Neighborhood Infill Overlay and URO may facilitate garage-to-ADU conversions in eligible districts. Zoning clearance is required to confirm the conversion complies with district regulations.

Key details: Permit: Building permit required. Building Code: 2018 ICC codes adopted. ADU Conversion: Allowed in Infill Overlay zones. Contact: Permit Center (918) 596-9456.

Unpermitted conversion: building code enforcement. Must bring to code or restore. Safety violations: immediate correction.

ADU Rules

Tulsa Zoning Code Chapter 45 (Accessory Uses and Structures) governs ADUs. Tulsa has been progressively liberalizing ADU rules. The Neighborhood Infill Overlay allows ADUs in certain residential districts without special approval. The Urban Residential Overlay (URO) permits ADUs and live-work units. Live-work units are restricted to 50% work area, capped at 2,500 sq ft. ADUs may include backyard cottages, garage apartments, and basement apartments.

Key details: Code Section: Ch. 45 (Accessory Uses). Infill Overlay: ADUs by right in some districts. Live-Work Cap: 50% work area, 2,500 sq ft max. Types: Cottage, garage apt, basement apt.

Unpermitted ADU: standard building code enforcement. May require demolition or legalization. Occupying unpermitted dwelling: code violation.

The Bottom Line

Tulsa's accessory structures rules are a mixed bag. Some areas are strict, others are relaxed, and the details matter. The best approach is to check the specific rule that applies to your situation rather than assuming Tulsa is broadly strict or permissive.

These rules come from Tulsa's publicly available municipal code. For complete penalty schedules, exemption details, and answers to common questions, see the individual ordinance pages throughout this guide.