Skip to main content
CityRuleLookup
🔊 Noise Ordinances/Decibel Limits

Decibel Limits: Carson vs Pasadena

How do decibel limits rules compare between Carson, CA and Pasadena, CA?

Carson has fewer restrictions than Pasadena.

Carson, CA

Los Angeles County

Some Restrictions

Carson Municipal Code Art. 4 Ch. 5 adopts LA County Code Title 12 Ch. 12.08 by reference. Section 12.08.390 sets exterior decibel standards by Noise Zone (defined in §12.08.380). Residential (Zone I): 50 dBA daytime 7 a.m.–10 p.m. / 45 dBA nighttime 10 p.m.–7 a.m. Commercial (Zone II): 65 dBA day / 60 dBA night. Industrial (Zone III): 70 dBA at all hours. The standards are measured at the property line of the receiving property. Graduated exceedance allowances (§12.08.390): base standard for 30+ min/hour; +5 dBA for 15–30 min/hr; +10 dBA for 5–15 min/hr; +15 dBA for 1–5 min/hr; +20 dBA for less than 1 min/hr; never above ambient + 20 dBA in any case. If the ambient L50 already exceeds the table value, ambient L50 becomes the baseline. Plainly-audible-from-100-feet (residential) and similar nuisance standards under §12.08.560 also apply for amplified sound, animals, and parties.

View full Carson rules →

Pasadena, CA

Los Angeles County

Heavy Restrictions

Pasadena prohibits noise exceeding the ambient level by more than 5 dB at any property line under PMC Section 9.36.050. Construction equipment limited to 85 dBA at 100 feet. Amplified sound on private property cannot exceed 15 dB above ambient. Interior noise in multifamily residential must not exceed 50 dBA.

View full Pasadena rules →

Key Facts Comparison

FactCarsonPasadena
Residential exterior limit50 dBA day (7a–10p) / 45 dBA night (10p–7a)-
Commercial exterior limit65 dBA day / 60 dBA night-
Industrial exterior limit70 dBA all hours-
Multi-family interior limit45 dBA day / 40 dBA night-
Measurement standardANSI Type 1/2 SLM, A-weighted, slow response (§12.08.220)-
Construction hours7 a.m.–7 p.m. weekdays; no Sunday/holiday (§12.08.440)-
Maximum exceedance+20 dBA for less than 1 min/hr; +15 dBA for 1–5 min/hr-
Penalty rangeUp to $1,000 + 6 mo jail (LA Co. §12.08.030) / Carson admin $100–$500-
Property Line-Ambient + 5 dB max
Construction-85 dBA at 100 ft
Interior (Multi)-50 dBA
Code-PMC Ch. 9.36

Highlighted rows indicate differences between cities.

Carson FAQ

What is Carson's nighttime residential noise limit?

45 dBA between 10 p.m. and 7 a.m., measured at your property line — per LA County Code §12.08.390 (Noise Zone I), adopted by Carson Municipal Code Art. 4 Ch. 5.

Do I need a sound level meter to file a noise complaint?

No. While the formal standard is a measured dBA reading, Carson Code Enforcement and the LA County Sheriff's Carson Station respond to plainly-audible-from-50-feet violations and may issue citations based on officer observation under LA County Code §12.08.560 (amplified sound) and §12.08.570 (animal noise).

What if my neighbor's stereo is loud but only for 5 minutes at a time?

Short-duration loud noise is still regulated by a graduated table — +15 dBA above the standard is allowed for 1–5 minutes per hour, but not more. Sustained amplified sound audible at 50 ft in a residential zone is a per se violation regardless of duration.

Are emergency generators and HVAC equipment regulated?

Yes — stationary mechanical equipment must comply with the property-line dBA limits. Carson's Building Code (CMC Art. 4) and CALGreen Title 24 Part 11 §5.507 also require noise attenuation for new commercial HVAC located near residential.

Pasadena FAQ

What is the noise limit in Pasadena?

Noise cannot exceed the ambient level by more than 5 decibels at any property line under PMC Section 9.36.050. Ambient is measured as a 15-minute average.

What is the construction equipment noise limit?

Individual pieces of construction equipment cannot generate noise exceeding 85 dBA at a distance of 100 feet under Section 9.36.070.

Want to add a third city?

Use our full comparison tool to compare up to three cities.