Smoke Detectors: Coral Gables vs Doral
How do smoke detectors rules compare between Coral Gables, FL and Doral, FL?
Coral Gables and Doral have similar restriction levels.
Coral Gables, FL
Miami-Dade County
Coral Gables enforces Florida Building Code, Residential Section R314 (smoke alarms) and the Florida Fire Prevention Code (NFPA 1 / NFPA 72). New construction and any permitted alteration, repair, or addition must install UL 217-listed alarms in every sleeping room, outside each sleeping area, and on every story, hardwired with battery backup and interconnected. F.S. 553.883 requires battery-only replacement alarms in existing 1-2 family homes to use sealed 10-year batteries.
View full Coral Gables rules βDoral, FL
Miami-Dade County
Doral enforces the Florida Building Code Residential R314 and the Florida Fire Prevention Code. Smoke alarms are required in every sleeping room, outside each sleeping area, and on every story including basements. Florida Statute 553.883 requires battery-only replacement alarms to be 10-year sealed lithium models, and Doral sits in the High Velocity Hurricane Zone with stricter installation expectations.
View full Doral rules βKey Facts Comparison
| Fact | Coral Gables | Doral |
|---|---|---|
| - | - | |
| Code Citation | - | FBC R314 |
| CO Alarm Citation | - | FBC R315 / FS 553.885 |
| 10-Year Battery | - | FS 553.883 |
| Power Source (New) | - | Hardwired + battery |
| Wind Zone | - | HVHZ (Miami-Dade) |
| Building Dept | - | 305-593-6700 |
Highlighted rows indicate differences between cities.
Coral Gables FAQ
Doral FAQ
Where do I have to install smoke alarms in a Doral home?
Under Florida Building Code Residential Section R314, smoke alarms must be installed inside every sleeping room, in the hallway or area immediately outside each separate sleeping area, and on every additional story including basements and habitable attics. New-construction alarms must be hardwired with battery backup and interconnected so that one activation sounds all alarms.
Do I need a 10-year battery smoke alarm in my Doral rental?
Yes, if you are installing a new battery-only alarm. Florida Statute 553.883 requires that any battery-powered smoke alarm installed on or after January 1, 2015 as a replacement use a non-removable, non-replaceable 10-year sealed lithium battery. Hardwired alarms with battery backup are exempt from the 10-year sealed requirement, but the FBC R314 hardwiring and interconnection rules still apply.
Compare other topics
See how Coral Gables and Doral compare on other ordinance categories.
Want to add a third city?
Use our full comparison tool to compare up to three cities.
Open Comparison Tool