Smoke Detectors: Miami Beach vs Miami
How do smoke detectors rules compare between Miami Beach, FL and Miami, FL?
Miami Beach, FL
Miami-Dade County
Miami Beach follows Florida Building Code Residential Section R314 and Florida Statute 553.883 for smoke alarms, plus F.S. 509.211 carbon monoxide rules for lodging. Alarms are required in every sleeping room, outside each separate sleeping area, and on every story including basements, with interconnection in new construction. Battery-only alarms installed or replaced after January 1, 2015 must use a sealed nonremovable 10-year battery.
View full Miami Beach rules βMiami, FL
Miami-Dade County
No data available yet for Miami.
Key Facts Comparison
| Fact | Miami Beach | Miami |
|---|---|---|
| Primary Code | Florida Building Code Residential Section R314 | - |
| Battery Standard | F.S. 553.883 β sealed 10-year battery (since Jan 1, 2015) | - |
| Required Locations | Each sleeping room, outside each sleeping area, every story | - |
| New Construction Power | Hardwired with battery backup, interconnected | - |
| Listing Standard | UL 217 / NFPA 72 | - |
| CO Alarm (lodging boilers) | F.S. 509.211 | - |
| CO Alarm (post-2008 buildings) | F.S. 553.885 β within 10 ft of each sleeping room | - |
| Inspection Authority | Miami Beach Fire Rescue annual fire inspection | - |
Highlighted rows indicate differences between cities.
Miami Beach FAQ
Miami FAQ
No FAQs available.
Compare other topics
See how Miami Beach and Miami compare on other ordinance categories.
Want to add a third city?
Use our full comparison tool to compare up to three cities.
Open Comparison Tool