New Britain, CT Fire Regulations: Propane Storage (2026)
Key Facts
- Applies to
- Tanks in special flood hazard areas
- Elevation option
- Concrete pad above base flood elevation
- Anchoring option
- Tie-down straps against flotation
- Fill pipe rule
- Raised above BFE, screw cap
- General LP-gas article
- Deleted from local fire code
- Fine
- $99 plus $99/day continuing
Summary
New Britain's own propane storage rule sits inside its flood damage prevention article, not a general fire code limit: Code of Ordinances § 9-43(h) requires any aboveground propane or oil tank in a special flood hazard area to be elevated on a concrete pad above the base flood elevation, or anchored with tie-down straps, with the fill pipe raised and a screw fill cap.
(h)Aboveground oil tanks. Aboveground storage tanks (oil, propane, etc.) which are located outside or inside of the structure must either be elevated above the base flood elevation (BFE) on a concrete pad, or be securely anchored with tie-down straps to prevent flotation or lateral movement, have the top of the fill pipe extended above the BFE, and have a screw fill cap that does not allow for the infiltration of flood water.
Full Breakdown
New Britain adopted the 1976 American Insurance Association Fire Prevention Code by reference in Sec. 8-66, but Sec. 8-67 expressly deleted Article 21, Liquified Petroleum Gases, from that adoption, so the city's own code does not carry a general LP-gas quantity or clearance limit for residential propane tanks; that leaves state and manufacturer standards to govern ordinary backyard tank placement. The one propane-specific rule the city code does contain sits in the flood damage prevention article at Sec. 9-43(h), which applies specifically to any aboveground oil or propane storage tank located inside or outside a structure within a special flood hazard area mapped on the city's FEMA flood insurance rate map.
Such a tank must either sit on a concrete pad elevated above the base flood elevation, or be secured with tie-down straps to prevent it from floating or shifting during flooding, and in either case the fill pipe must extend above the base flood elevation and carry a screw fill cap that keeps floodwater from entering the tank. This requirement runs alongside the broader flood-hazard reduction standards in Sec. 9-45, which require new construction to be anchored against flotation and built with flood-resistant materials, and it is enforced by the city engineer, who administers the article under Sec.
9-44 and can order a violation corrected or issue a stop-work order under Sec. 9-49. A homeowner in a mapped flood zone adding or replacing an aboveground propane tank needs to meet this anchoring standard as part of any floodplain management permit application.
Violations & Fines
An aboveground propane or oil tank in a special flood hazard area that is not elevated on a compliant concrete pad or properly tied down is a violation of Sec. 9-43(h), enforced under Sec. 9-50 as a misdemeanor: a $99 fine plus a further $99 for each additional day the noncompliant tank remains in place, with the city engineer authorized to order corrective work under Sec. 9-49.
Frequently Asked Questions
Does New Britain limit how much propane I can store at my house?
What does New Britain require for a propane tank in a flood zone?
Sources & Official References
Other rules in New Britain
Compare New Britain to another location·View the Connecticut fire regulations overview
See something wrong?
Help us keep this page accurate. If you notice an error or outdated information, let us know.