Toledo, OH Building Safety: Door Locking Hardware (2026)
Key Facts
- Governing rule
- Locks/fasteners barred on required egress doors
- Institution exception
- 24-hour trained supervisory staff required
- Security-area exception
- Pre-approval required before installation
- Flush bolts
- Manually operated flush bolts prohibited outright
- Enforcing agency
- Division of Building Inspection
- Adopted by
- Ordinance 131-15, passed 3-31-15
Summary
Toledo's Property Maintenance Code bars locks or fasteners on required egress doors in most buildings. Toledo Municipal Code § 1367.03, amending IPMC § 702.3, permits locking hardware only in penal or mental institutions with continuous trained supervision, in approved high-security areas using pre-approved alarms, or where hardware meets standards the Ohio Building Code allows. Manually operated flush bolts are flatly banned.
IPMC-702.3 Locked doors (Amended): Locks or fasteners shall not be installed on egress doors except in accordance with the following conditions: 1. In mental, penal or other institutions where the security of inmates is necessary, in which case properly trained supervisory personnel shall be continuously on duty and approved provisions are made to remove occupants safely in case of fire or other emergency. 2. In problem security areas, special-purpose door alarms or locking devices shall be approved prior to installation. Manually operated edge or surface-molded flush bolts are prohibited. 3. Where the door hardware conforms to that permitted by the Ohio Building Code.
Official source re-checked September 7, 2026: no newer edition of the code had been published (publisher’s edition: 2026 S-105: Complete to June 30, 2026).
Full Breakdown
3 ("Locked doors") for every existing residential and commercial structure covered by the Ohio Building Code and Residential Code of Ohio. The default rule is a prohibition: no locks or fasteners on doors serving as required means of egress. Three narrow exceptions apply. First, mental, penal or similar institutions may lock occupants in only where trained supervisory staff are on duty around the clock and there are approved plans to evacuate occupants safely during a fire or other emergency. Second, designated "problem security areas" may use special-purpose door alarms or locking devices, but only after the Division of Building Inspection approves the specific hardware before installation, manually operated edge or surface-mounted flush bolts are prohibited outright, with no case-by-case waiver described in the text.
Third, hardware that independently conforms to what the Ohio Building Code permits is allowed. 01) is protecting public health, safety and welfare by fixing owner and operator responsibility and "providing for administration, enforcement and penalties," and the amendments were adopted by Ordinance 131-15, passed March 31, 2015. 2, also amended locally, requires egress-corridor doors over a 30-occupant threshold to be self-closing or kept closed, reinforcing that hardware on exit routes is tightly constrained rather than left to a building owner's preference.
Violations & Fines
Toledo's Division of Building Inspection enforces the Property Maintenance Code under Chapter 1367. Because § 702.3 is folded into the chapter enacted for "administration, enforcement and penalties," installing or leaving in place a prohibited lock, fastener or flush bolt on a required egress door is a code violation subject to inspection, a correction order, and prosecution as a Property Maintenance Code offense if not remedied; unapproved security hardware found during an inspection must be removed or replaced with hardware that fits one of the three listed exceptions.
Frequently Asked Questions
Can a Toledo apartment building add a deadbolt to a stairwell exit door?
Are keyed flush bolts on double exit doors allowed in Toledo?
Who approves special security locks on Toledo exit doors?
Sources & Official References
Other rules in Toledo
Compare Toledo to another location·View the Ohio building safety overview
See something wrong?
Help us keep this page accurate. If you notice an error or outdated information, let us know.