Fences in unincorporated San Diego County must meet Section 6708 zoning height and location limits and, where a permit applies, the construction standards in County handout PDS-070. Requirements cover footing depth, fire-resistive materials near buildings in WUI areas (Section 707A), and clearances for gates and fire access. Pool barriers and visibility rules add further requirements.
A compliant fence in unincorporated San Diego County must satisfy both zoning and building requirements. Zoning (Section 6708) sets height by location - 42 inches in front/exterior side yards, 72 inches in rear/interior side yards, with rural and administrative exceptions. Gates and gate entry structures may not exceed 12 feet, must sit at least 10 feet from a public road right-of-way or private road easement they access, and must preserve a minimum 13-foot 6-inch vertical clearance for fire-protection vehicles (Section 6708(d) and (e)); the County Fire Code and local fire district ordinances govern gates across fire-access roads. Construction standards from handout PDS-070 require, among other things, posts set in 12-inch-diameter concrete footings extending at least 24 inches into undisturbed natural ground or properly compacted fill, with prescriptive masonry footing and reinforcing tables (Table A). In Wildland-Urban Interface (WUI) areas, any portion of a fence within 5 feet of a building must be non-combustible or approved fire-retardant material meeting Section 707A of the County Building Code. Fences that confine animals must also conform to the Animal Regulations beginning at Section 3000. Swimming-pool enclosure barriers are separately required under the adopted California Building Code/state pool-safety law. Where a fence sits in a required yard, it must not create traffic-visibility hazards, a finding the Director must make when granting fence exceptions under Section 6708(h).
Fences that violate Section 6708 height, location, gate-clearance, or fire-access requirements, or that lack a required building permit, are enforced by PDS Code Compliance and the Building Division. WUI fire-material violations and pool-barrier deficiencies are enforced under the County Building Code, and may require correction or removal.
Other ordinances people look up for this city. Green dot = verified primary-source excerpt.
Chula Vista, CA
CVMC 19.68.030 establishes specific exterior noise level limits by zoning district. Single-family residential zones are limited to 55 dBA daytime and 45 dBA ...
Chula Vista, CA
Leaf blowers and power fans in Chula Vista must be equipped with muffler devices under CVMC 19.68.050. Operation is prohibited during nighttime hours (10 PM ...
Chula Vista, CA
Chula Vista's quiet hours are effectively 10 PM to 7 AM on weekdays and 10 PM to 8 AM on weekends, when lower nighttime noise limits apply under CVMC 19.68. ...
Chula Vista, CA
Chula Vista has adopted an expedited permitting process for electric vehicle charging stations under CVMC 15.29.030 pursuant to California Government Code se...
Chula Vista, CA
Vehicles in Chula Vista must park on improved driveway surfaces. Parking on front lawns, unpaved areas, or blocking sidewalks is prohibited. Driveway modific...
Chula Vista, CA
Chula Vista addresses animal hoarding through keeping limits in Chula Vista Municipal Code Title 6 and through the Chula Vista Animal Care Facility, the only...
Side-by-side rule comparisons with other cities in San Diego County.
See how other cities in San Diego County handle fence requirements.
See how Chula Vista's fence requirements rules stack up against other locations.
Quick Compare
Help us keep this page accurate. If you notice an error or outdated information, let us know.