Skip to main content
CityRuleLookup

Seminole County, FL Building Safety: Carbon Monoxide Detectors (2026)

Light Restrictions
Compiled from the official code textEditor Martyn O'NeillLast verified September 2026

Key Facts

Governing section
Sec. 107.3.5, item 6
Applies to
one- and two-family residential permits
Reviewed by
Seminole County building official
Consequence
rejection or permit revocation, Sec. 104.2.1

Summary

Before issuing a residential building permit, the Seminole County building official reviews plans for smoke and carbon monoxide alarm and detector locations under Section 107.3.5's minimum plan review criteria, alongside egress, structural and flood-hazard requirements for one- and two-family homes.

These county ordinances apply to unincorporated areas of Seminole County. Incorporated cities within the county may have their own rules that take precedence over county-level regulations.

107.3.5 Minimum plan review criteria for buildings. The examination of the documents by the building official shall include the following minimum criteria and documents; a floor plan; site plan; foundation plan; floor/roof framing plan or truss layout; all fenestration and building envelope penetrations; flashing; and rough opening dimensions; and all exterior elevations: ... Residential (one- and two-family) Building. 1. Site requirements: 2. Set back/separation (assumed property lines) 3. Location of septic tanks 4. Fire-resistant construction (if required) 5. Fire 6. Smoke and/or carbon monoxide alarm/detector locations

View official code

Official source re-checked September 7, 2026: no newer edition of the code had been published (publisher’s edition: Code of Ordinances: Supplement 23 Update 1 | Land Development Code: Supplement 2).

Full Breakdown

5 sets the minimum plan review criteria the Seminole County building official applies before approving any building permit application. For a floor plan, site plan and foundation plan to pass review at all, the examination must cover fenestration, envelope penetrations, flashing and rough opening dimensions plus, for one- and two-family residential building, a specific checklist: site requirements, setback and separation distances, septic tank location, fire-resistant construction where required, and item 6, smoke and/or carbon monoxide alarm and detector locations. The same residential checklist requires the plans to show flood hazard areas, flood zones, design flood elevations, lowest floor elevations and flood damage-resistant materials, and separately requires egress window size, location and stairs construction.

1 conditions the building official's written or stamped approval, marked Reviewed for Code Compliance, on the documents satisfying this section. 1 can revoke a permit already issued in error or based on incomplete information, forcing the applicant to resubmit plans identifying every required smoke and carbon monoxide detector location before construction can proceed.

Violations & Fines

Submitting residential building plans without the smoke and carbon monoxide alarm and detector locations Section 107.3.5 requires means the plans fail minimum review criteria: the building official can reject the application outright, and if a permit issued despite the omission, Section 104.2.1 lets the official suspend or revoke it as issued on incomplete information until corrected plans are filed.

Frequently Asked Questions

Does Seminole County require CO detector locations on my building plans?
Yes, for one- and two-family residential building permits. Section 107.3.5's minimum plan review criteria list smoke and/or carbon monoxide alarm/detector locations as item 6 the building official must find on your submitted plans before approving the permit.
What happens if my plans leave out detector locations?
The plans fail the minimum review criteria in Section 107.3.5, so the building official can reject the application; if a permit was mistakenly issued anyway, Section 104.2.1 authorizes the official to suspend or revoke it until corrected plans are submitted.
Does this apply to my rental in Sanford or Oviedo?
No. This building-plan review requirement is part of unincorporated Seminole County's Building and Construction Code Appendix A; Sanford, Oviedo, Altamonte Springs and the county's other incorporated cities administer their own building permit review under their own adopted codes.

Sources & Official References

Other rules in Seminole County

All Seminole County rules

Florida rules heatmap·Compare Seminole County to another location·View the Florida building safety overview

Get notified when Carbon Monoxide Detectors in Seminole County, FL changes

We'll email you the moment we detect a change in the code. No spam, unsubscribe anytime.

We'll never sell or share your email. One-click unsubscribe in every email.

See something wrong?

Help us keep this page accurate. If you notice an error or outdated information, let us know.