Prince George's County, MD Building Safety: Green Building Code (2026)

Some Restrictions
Compiled from the official code textEditor Martyn O'NeillLast verified August 2026

Key Facts

SHGC limit, Climate Zone 4
.40 lowered to .35
Occupant sensor cutoff
Lights off within 30 minutes
Sensor restart cap
50 percent lighting power
Renewable energy option
0.50 watts per sq ft
Alternate compliance path
5% of regulated energy use

Summary

Prince George's County tightens the International Energy Conservation Code's commercial provisions in Code §§ 4-257, 4-258, and 4-261: window solar heat gain in Climate Zone 4 drops from .40 to .35, occupant sensors must cut lighting within 30 minutes of a room clearing, and covered buildings must add on-site renewable energy meeting a set threshold.

These county ordinances apply to unincorporated areas of Prince George's County. Incorporated cities within the county may have their own rules that take precedence over county-level regulations.

Table C402.3 is amended to read as follows: SHGC is Climate Zone 4 is changed from .40 to .35. … Section C405.2.1 Occupant sensor controls shall be installed in all classrooms, conference/meeting rooms, employee lunch and break rooms, private offices, restrooms, storage rooms, janitorial closets, enclosed stairways, and other spaces 300 square feet (28m2) or less enclosed by floor-to-ceiling height partitions. These automatically turn off lights within 30 minutes of all occupants leaving the space, and shall turn the lighting on to not more than 50 percent power. … Section C406.5. Total minimum ratings of on-site renewable energy systems shall comply with one of the following: 1. Provide not less than 1.75 Btu (1850 W), or not less than 0.50 watts per square foot (5.4 W/m2) or conditioned floor area. 2. Provide not less than 5 percent of the energy used within the building for building mechanical and service water heating equipment and lighting regulated in this chapter.

View official code

Official source re-checked September 7, 2026: no newer edition of the code had been published (publisher’s edition: Code of Ordinances: Supplement 2026 Update 2).

Full Breakdown

Subtitle 4's amendments to the 2021 International Energy Conservation Code (Commercial) tighten several numeric thresholds beyond the base IECC. 35, cutting how much solar heat new commercial glazing can admit. Section 4-258 requires occupant sensor controls, not plain light switches, in every classroom, conference or meeting room, employee lunch or break room, private office, restroom, storage room, janitorial closet, enclosed stairway, and any other space of 300 square feet or less enclosed by floor-to-ceiling partitions; those sensors must cut the lights within 30 minutes of the last occupant leaving and can bring lighting back on to no more than 50 percent power.

A related amendment, Section 4-259, requires parking-area lighting controls to cut power density by 30 percent after 15 minutes of non-activity. 50 watts per square foot of conditioned floor area, or generate at least 5 percent of the energy the building's regulated mechanical, service water heating, and lighting systems consume. These sections were added by CB-45-2012, with the lighting-control provisions further amended by CB-90-2015, folding successive IECC commercial-energy updates directly into the county's own Subtitle 4 rather than leaving the state model code to control unmodified.

Violations & Fines

DPIE's plan review rejects a commercial permit application whose glazing schedule shows a solar heat gain coefficient above .35 for Climate Zone 4, or whose lighting design omits the required occupant sensors, until the drawings are corrected. A certificate of occupancy will not issue for a covered building that skips the on-site renewable energy requirement in Section 4-261.

Frequently Asked Questions

Does Prince George's County have its own green building code?
The county does not run a separate green building code; it amends the 2021 International Energy Conservation Code's commercial provisions directly in Subtitle 4, tightening window performance under Section 4-257, adding occupant-sensor lighting controls under Section 4-258, and requiring on-site renewable energy under Section 4-261.
How much on-site renewable capacity does a new commercial building need?
Section 4-261 gives two paths: install a renewable system rated at least 1.75 Btu (1,850 watts) or 0.50 watts per square foot of conditioned floor area, or generate at least 5 percent of the energy the building's regulated mechanical, water-heating, and lighting equipment consumes, whichever path the design team chooses.
What spaces need occupant-sensor lighting controls?
Section 4-258 requires occupant sensor controls in classrooms, conference and break rooms, private offices, restrooms, storage rooms, janitorial closets, enclosed stairways, and any other floor-to-ceiling partitioned space of 300 square feet or less, with lights required to shut off automatically within 30 minutes of the space clearing.

Sources & Official References

Other rules in Prince George's County

All Prince George's County rules

Compare Prince George's County to another location·View the Maryland building safety overview

Get notified when Green Building Code in Prince George's County, MD changes