Key Facts

Governing section
Zoning Ordinance § 822.3.060
Measurement point
Curb level or front finished grade to highest point
Excludes
Chimneys and ventilators from height measurement
Assembly facility bonus
Up to 25 extra feet with added setbacks
Misc. structure bonus
Up to 50% above zone maximum height
Penalty
Misdemeanor, up to $500 fine or 180 days jail

Summary

Fresno County measures building height and sets maximum limits by zone under Zoning Ordinance Section 822.3.060. Height runs from the adjoining curb level, or from finished grade at the front of a setback structure, up to the highest point, excluding chimneys and ventilators, with limited increases allowed for specific structure types.

City-specific rules exist: Clovis, and Fresno have their own structure height limits rules that differ from Fresno County's county-level regulations. If you live in one of those cities, check the city-specific page instead.

822.3.060 - Height Measurement and Height Limit Exceptions

All structures shall meet the standards in this Section relating to height, except for fences and walls, which shall comply with Section 822.3.050 (Fences, Walls, and Hedges). A. Maximum height allowed. The height of structures shall not exceed the standards established by the applicable zone in Article 2 (Zones, Allowable Land Uses, and Zone-Specific Standards), except as otherwise provided in this Section. B. Height measurement. Height shall be measured as the vertical distance from the adjoining curb level to the highest point of the structure, exclusive of chimneys and ventilators; provided, however, that where structure(s) is set back from the street line, the height shall be measured from the average elevation of the finished grade at the front of the structure(s).

Source: Fresno County Code Title 18 - ZoningView official code

Full Breakdown

050. Subsection A caps structure height at whatever the applicable base zone establishes in Article 2's zone-specific standards tables; the ordinance does not set one flat countywide number, so the limit differs by zone. Subsection B fixes how height is measured: as the vertical distance from the adjoining curb level to the structure's highest point, excluding chimneys and ventilators, except that where a structure is set back from the street line, height is measured from the average finished grade at the front of the structure.

Subsection C allows specific increases above the zone's base limit. Assembly and meeting facilities in zones with a 35-foot or lower limit may add up to 25 feet if front, side, and rear setbacks each increase by one additional foot for every four feet of height added above 35 feet. A separate list of miscellaneous structures, including farm barns and silos in the RC and RE zones, agricultural cupolas and observation towers, flag poles, fire and hose towers, water tanks, and noncommercial antennae up to 65 feet, may exceed the zone's maximum structure height by up to 50 percent, or more if a land use permit specifies a greater height. All increases must still comply with airport safety regulations and any conditions of an approved land use permit.

Violations & Fines

Building above the height allowed for a parcel's zone, without qualifying for one of Section 822.3.060's listed exceptions or an approved land use permit increase, violates the Zoning Ordinance. Section 878.6.030 makes the violation a misdemeanor: a fine up to $500, up to 180 days in county jail, or both, charged as a separate offense for each day the excess height remains uncorrected.

Frequently Asked Questions

How is building height measured in unincorporated Fresno County?
Section 822.3.060 measures height as the vertical distance from the adjoining curb level to the structure's highest point, not counting chimneys and ventilators. If the structure sits back from the street line, the county instead measures from the average finished grade at the front of the structure to its highest point.
Can a barn or water tank exceed the normal height limit?
Yes. Section 822.3.060(C)(2) lists specific structures, including farm barns and silos in the RC and RE zones, cupolas, flag poles, fire towers, water tanks, and noncommercial antennae up to 65 feet, that may exceed the zone's maximum structure height by up to 50 percent, or more under an approved land use permit's conditions.
Do fences count toward the zoning height limit?
No. Section 822.3.060 expressly excludes fences and walls from its height standard, sending them instead to Section 822.3.050, which sets separate height limits by zone, setback location, and whether the fence is in a front, side, or rear yard.

Sources & Official References

Other rules in Fresno County

All Fresno County rules

California rules heatmap·Compare Fresno County to another location·View the California building setbacks & zoning overview

Get notified when Structure Height Limits in Fresno County, CA changes

We'll email you the moment we detect a change in the code. No spam, unsubscribe anytime.

We'll never sell or share your email. One-click unsubscribe in every email.

See something wrong?

Help us keep this page accurate. If you notice an error or outdated information, let us know.

Structure Height Limits in Cities Across Fresno County