Key Facts

Freeboard standard
1 foot above base flood elevation
Applies to
residential, nonresidential, manufactured homes
Critical facilities standard
500-year flood elevation
Proof required
FEMA elevation certificate (Form 81-31)
Penalty
up to $1,000 fine, 90 days jail
Variance
rare, hardship-only, per SCC 3.20.440

Summary

Spokane County requires new and substantially improved buildings in a mapped flood hazard area to sit at least one foot above the base flood elevation, the Flood Protection Elevation defined in SCC 3.20.100. Residential structures must clear that freeboard at the lowest floor under SCC 3.20.610(a), while manufactured homes and nonresidential buildings face the same one-foot minimum.

These county ordinances apply to unincorporated areas of Spokane County. Incorporated cities within the county may have their own rules that take precedence over county-level regulations.

"Flood Protection Elevation" means one foot above the base flood elevation. ... 3.20.610(a) New construction and substantial improvement of any residential structure within areas of special flood hazard shall have the lowest floor, including basement, elevated a minimum of one foot above the base flood elevation. New construction and substantial improvement of any residential structure outside the floodplain on property a portion of which is in a special flood hazard area shall have the lowest opening of the structure elevated a minimum of one foot above the base flood elevation.

View official code

Official source re-checked September 7, 2026: no newer edition of the code had been published (publisher’s edition: Code of Ordinances: Supplement 63).

Full Breakdown

100 defines Flood Protection Elevation as one foot above the base flood elevation, the county's freeboard standard layered on top of FEMA's mapped 100-year base flood level. 610(a) applies it to homes: new construction and substantial improvements must have the lowest floor, including basement, elevated a minimum of one foot above the base flood elevation, and even a residential structure outside the floodplain but on a lot partly inside one must elevate its lowest opening the same one foot. 610(b). 620 get the same one-foot freeboard option or can dry-floodproof to that level with an engineer's or architect's certification.

510(b). 230: their lowest floor must clear the five-hundred-year flood level, not just one foot over the ordinary base flood. Every one of these elevations gets documented on a FEMA elevation certificate, Form 81-31, completed by a Washington-licensed surveyor with Section B verified by the county engineer/public works director before the county will sign off.

Violations & Fines

Building below the required freeboard, or skipping the elevation certificate, is a floodplain development permit violation under SCC 3.20.720: a misdemeanor carrying up to a $1,000 fine, 90 days in jail, or both, plus a stop-work order under 3.20.730 halting construction until the deficiency is fixed. Variances below the one-foot standard are rare and hardship-only under 3.20.440, and any owner who gets one must be told in writing that flood insurance costs will rise accordingly.

Frequently Asked Questions

How much higher than the base flood elevation must my house sit?
One foot. SCC 3.20.100 defines Flood Protection Elevation as one foot above the base flood elevation, and SCC 3.20.610(a) requires new or substantially improved residential structures to have their lowest floor, including any basement, built to that height.
Does a garage or storage building need the same freeboard?
Accessory residential structures can skip the lowest-floor elevation requirement if they are wet floodproofed per FEMA Technical Bulletin 7 and meet the anchoring, materials and venting standards in SCC 3.20.610(d), instead of building the structure a full foot above base flood elevation.
What about a hospital or fire station?
Critical facilities are held to a tougher standard than ordinary buildings: SCC 3.20.230 requires their lowest floor at or above the five-hundred-year flood level, well beyond the one-foot freeboard that applies to ordinary residential and nonresidential construction.

Sources & Official References

Other rules in Spokane County

All Spokane County rules

Compare Spokane County to another location·View the Washington environmental rules overview

Get notified when Flood Elevation Requirements in Spokane County, WA changes

We'll email you the moment we detect a change in the code. No spam, unsubscribe anytime.

We'll never sell or share your email. One-click unsubscribe in every email.

See something wrong?

Help us keep this page accurate. If you notice an error or outdated information, let us know.

Flood Elevation Requirements in Cities Across Spokane County