Okaloosa County, FL Environmental Rules: Flood Elevation Requirements (2026)

Some Restrictions
Compiled from the official code textEditor Martyn O'NeillLast verified September 2026

Key Facts

Zone V, Okaloosa Island min.
9.6 ft NAVD 1988
Critical facilities standard
500-year flood elevation
Accessory structure cap, Zone A
600 sq ft below BFE
Accessory structure cap, Zone V
100 sq ft below BFE
Governing section
LDC § 3.06.10

Summary

Okaloosa County requires new and substantially improved buildings in flood hazard areas to meet minimum elevation standards under the Florida Building Code and ASCE 24, and it goes further on Okaloosa Island: buildings in Zone V there must have their lowest structural support member at or above 9.6 feet NAVD 1988, regardless of what the base Building Code would otherwise require.

These county ordinances apply to unincorporated areas of Okaloosa County. Incorporated cities within the county may have their own rules that take precedence over county-level regulations.

C. Minimum elevation requirements for buildings in flood hazard areas. The minimum elevation requirements for buildings in flood hazard areas, including new construction and substantially improved buildings, are specified in: (1) The Florida Building Code, Building by reference to ASCE 24. (2) The Florida Building Code, Residential, in Section R322.2 (Zone A) and Section R322.3 (Zone V and Coastal A Zone). D. Minimum elevation requirement for buildings in Zone V on Okaloosa Island. In addition to the requirements of the Florida Building Code, new construction and substantially improved buildings and structures in Zone V on Okaloosa Island shall be elevated such that the bottom of the lowest horizontal structural member supporting the lowest floor is at or above the elevation required by the Florida Building Code, but no lower than 9.6 feet NAVD 1988. F. Critical facilities. Critical facilities shall be elevated or protected from damage and loss of access during flood events up to and including the 500-year flood elevation in accordance with the Florida Building Code requirements for Flood Design Class 4.

View official code

Official source re-checked September 7, 2026: no newer edition of the code had been published (publisher’s edition: Code of Ordinances: Supplement 23).

Full Breakdown

10 sets the elevation rules for buildings and structures in Okaloosa County's flood hazard areas. 3 for Zone V and Coastal A Zones. 6 feet NAVD 1988, whichever elevation is higher. 2 in Zone A, or just 100 square feet with no space beneath an elevated building in coastal high hazard Zone V, plus anchoring against flotation and flood-damage-resistant materials below the base flood elevation plus one foot. Critical facilities, meaning buildings a Flood Design Class 4 designation covers along with certain nursing homes and vital utility facilities, are held to a still higher standard: elevation or flood protection up to and including the 500-year flood elevation, not merely the 1-percent-annual-chance base flood.

Violations & Fines

Elevation noncompliance is enforced the same way as any other Floodplain Management Ordinance violation under section 3.06.09: a building without the lowest-floor elevation certification required by section 3.06.07 is presumed to be in violation until the owner supplies it, and enforcement runs through Article VI of Chapter 11 of the Code of Ordinances, up to and including denial or revocation of the development permit under section 3.06.05.F.

Frequently Asked Questions

Is there a stricter flood-elevation rule for Okaloosa Island than the rest of the county?
Yes. Section 3.06.10.D requires new construction and substantially improved buildings in Zone V on Okaloosa Island to have the bottom of the lowest supporting structural member at or above 9.6 feet NAVD 1988, even if the Florida Building Code's standard elevation requirement would otherwise allow a lower floor.
Can I build a shed below the base flood elevation in a flood zone?
Only if it's a detached accessory structure used solely for parking or storage: up to 600 square feet with compliant flood openings in Zone A, or up to 100 square feet with no space under an elevated building in coastal high hazard Zone V, both anchored and built with flood-damage-resistant materials under section 3.06.10.E.
What flood standard applies to hospitals and fire stations?
Critical facilities, including Flood Design Class 4 buildings, certain nursing homes, and vital utility infrastructure, must be elevated or otherwise protected up to and including the 500-year flood elevation under section 3.06.10.F, a materially higher bar than the 1-percent-annual-chance base flood elevation used for ordinary construction.

Sources & Official References

Other rules in Okaloosa County

All Okaloosa County rules

Florida rules heatmap·Compare Okaloosa County to another location·View the Florida environmental rules overview

Get notified when Flood Elevation Requirements in Okaloosa County, FL changes

We'll email you the moment we detect a change in the code. No spam, unsubscribe anytime.

We'll never sell or share your email. One-click unsubscribe in every email.

See something wrong?

Help us keep this page accurate. If you notice an error or outdated information, let us know.