Key Facts

Governing rule
Lake County Code § 6-22 (amending FBC R322.2.1)
Standard freeboard
18 in. above base flood elevation
Coastal A Zone freeboard
1 ft (305 mm) above base flood elevation
Zone AO minimum
FIRM depth number or 2 ft, whichever applies
Utilities/equipment
18 in. above base flood elevation (§ 1612.4)

Summary

New homes in a Lake County flood hazard area must be built with 18 inches of freeboard above the base flood elevation, not just built to the base flood line itself. Lake County Code § 6-22 amends Florida Building Code Section R322.2.1 to raise that bar, with a one-foot minimum instead in Coastal A Zones.

These county ordinances apply to unincorporated areas of Lake County. Incorporated cities within the county may have their own rules that take precedence over county-level regulations.

R322.2.1 Elevation requirements.

1.Buildings and structures in flood hazard areas not designated as Coastal A Zones shall have the lowest floors elevated to or above the base flood elevation, plus eighteen (18) inches or the design flood elevation, whichever is higher.2.Buildings and structures in flood hazard areas designated as Coastal A Zones shall have the lowest floors elevated to or above the base flood elevation plus one (1) foot (three hundred five (305) mm), or to the design flood elevation, whichever is higher.3.In areas of shallow flooding (AO Zones), buildings and structures shall have the lowest floor (including basement) elevated at least as high above the highest adjacent grade as the depth number specified in feet on the FIRM, or at least two (2) feet (six hundred ten (610) mm) if a depth number is not specified.4.Basement floors that are below grade on all sides shall be elevated to or above the base flood elevation, plus eighteen (18) inches or the design flood elevation, whichever is higher. Exception: Enclosed areas below the design flood elevation, including basements whose floors are not below grade on all sides, shall meet the requirements of Section R322.2.2.

(k)Modify, Building Section 1612.4, FBC, as follows:

View official code

Official source re-checked September 7, 2026: no newer edition of the code had been published (publisher’s edition: Code of Ordinances: Supplement 150).

Full Breakdown

Florida's building code sets the base flood elevation as the minimum floor height in a flood hazard area, but Lake County builds in extra margin, called freeboard, through a local amendment. 1 so that buildings and structures in flood hazard areas not designated as Coastal A Zones must have their lowest floors elevated to or above the base flood elevation plus 18 inches, or to the design flood elevation, whichever ends up higher. In Coastal A Zones the amendment requires at least one foot (305 mm) above base flood elevation instead, again deferring to the design flood elevation if that number is higher.

The same local amendment covers shallow flooding areas mapped as Zone AO, where the lowest floor, including any basement, has to sit at least as high above the highest adjacent grade as the depth number printed on the FIRM, or at least two feet if the map doesn't list a depth number, and it applies the same 18-inch-above-base-flood-elevation floor to basements that are below grade on every side. 4 so that utilities and attendant equipment, meaning mechanical, plumbing, and electrical equipment, must be elevated to 18 inches above the base flood elevation or as specified in ASCE 7/ASCE 24, whichever is higher. 2.

Violations & Fines

Building or substantially improving a structure in a Lake County flood hazard area without meeting the 18-inch freeboard standard (or one foot in a Coastal A Zone) is a violation of the locally amended Florida Building Code enforced through the county's building permit and inspection process under § 6-22. A structure that doesn't meet the required lowest-floor elevation can be denied a certificate of occupancy, and the Floodplain Administrator can require an elevation certificate from a Florida-licensed surveyor before further vertical construction proceeds, with non-compliance handled through code enforcement and potential National Flood Insurance Program rating consequences for the property.

Frequently Asked Questions

How much higher than base flood elevation must my new Lake County home be built?
At least 18 inches above the base flood elevation, or the design flood elevation if that's higher, under Lake County Code § 6-22's amendment to FBC Residential Section R322.2.1. In a Coastal A Zone the minimum freeboard drops to one foot above base flood elevation instead.
Does the freeboard requirement apply to basements?
Yes. Basement floors that are below grade on all sides must be elevated to or above the base flood elevation plus 18 inches, or to the design flood elevation if higher, the same standard used for a home's lowest floor under § 6-22's amendment to R322.2.1.
What about air conditioning and electrical equipment in a flood zone?
Lake County's amendment to FBC Section 1612.4 requires mechanical, plumbing, and electrical equipment serving a building in a flood hazard area to be elevated to 18 inches above base flood elevation, or as specified in ASCE 7 or ASCE 24, whichever is higher.

Sources & Official References

Other rules in Lake County

All Lake County rules

Florida rules heatmap·Compare Lake County to another location·View the Florida environmental rules overview

Get notified when Flood Elevation Requirements in Lake County, FL changes

We'll email you the moment we detect a change in the code. No spam, unsubscribe anytime.

We'll never sell or share your email. One-click unsubscribe in every email.

See something wrong?

Help us keep this page accurate. If you notice an error or outdated information, let us know.