Washington County, OR Fire Regulations: Brush Clearance (2026)

Significant Restrictions
Compiled from the official code textEditor Martyn O'NeillLast verified September 2026

Key Facts

Primary fuel-free break
30 feet minimum around structure
Secondary fuel-free break
additional 100 feet
Break widens with slope
up to +150 ft added zone at 40% slope
Break must be on
land owner controls, not neighbor's land
Companion standards
fire-retardant roof, spark arrester on chimney

Summary

Owners of dwellings and structures in the EFC forest zone must maintain a 30-foot fuel-free primary fire break around the building, plus an additional 100-foot fuel-free secondary break, with the primary break widening further on steeper slopes under a county dimensional table.

These county ordinances apply to unincorporated areas of Washington County. Incorporated cities within the county may have their own rules that take precedence over county-level regulations.

D. Fire Break Area Requirements. The owner(s) of dwellings and structures, including replacement dwellings and accessory structures, shall: (1) Maintain a minimum 30-foot primary fuel-free fire break area around the dwelling or structure. As slopes increase, the distance of the primary fire break area shall be increased around the dwelling or structure in accordance with the dimensional requirements in Table A; (2) Maintain an additional 100-foot secondary fuel-free fire break area around the primary firebreak encircling the dwelling or structure; and (3) Any required fire break shall be on land that is owned or controlled by the owner of the subject property.

View official code

Official source re-checked September 7, 2026: no newer edition of the code had been published (publisher’s edition: Community Development Code: Supplement 2 | Code of Ordinances: Supplement 25).

Full Breakdown

D requires owners of dwellings and structures, including replacement dwellings and accessory structures in the EFC District, to maintain a minimum 30-foot primary fuel-free fire break area around the building. That distance is not fixed: Table A increases the primary safety zone's additional buffer as slope rises, adding a 50-foot additional safety zone at 10% slope, 75 feet at 20% slope, 100 feet at 25% slope, and 150 feet at 40% slope, on top of the base 30-foot primary zone. Owners must also maintain an additional 100-foot secondary fuel-free fire break encircling the primary break.

Any required fire break must sit on land the property owner owns or controls, meaning a firebreak cannot be maintained on a neighbor's parcel. B must meet these same fire break requirements to the extent the existing building setbacks allow. The fuel-free break requirement pairs with related structural standards in the same section: structures cannot be sited on a slope greater than 40%, must have a fire-retardant roof, and any chimney must carry a spark arrester. 5 separately requires roads and driveways serving these structures to be built and maintained to standards approved by the local fire protection agency, with written confirmation required before both preliminary and final building inspection.

Violations & Fines

Failure to maintain the required 30-foot primary and 100-foot secondary fuel-free fire breaks is a standard the county checks at building permit review under Section 428-3.4.D; a permit will be denied or conditioned where an existing violation is on file per Section 215-2, and violations are prosecuted under Chapter 1.14 of the Washington County Code per Section 215-3.

Frequently Asked Questions

How large a fuel-free zone do I need around my house in the EFC zone?
Section 428-3.4.D requires a minimum 30-foot primary fuel-free fire break around the dwelling or structure, plus an additional 100-foot secondary fuel-free break encircling the primary one; the primary zone's buffer grows further as the site's slope increases under the county's Table A.
Can my fire break extend onto my neighbor's land?
No. Section 428-3.4.D.3 requires that any required fire break sit only on land owned or controlled by the owner of the subject property, so the 30-foot and 100-foot clearance zones must fit within the applicant's own parcel.
Does slope change how much brush I have to clear?
Yes. The county's Table A under Section 428-3.4.D adds to the primary safety zone as slope increases: 50 additional feet at 10% slope, 75 feet at 20%, 100 feet at 25%, and 150 feet at 40% slope, on top of the base 30-foot primary fire break.

Sources & Official References

Other rules in Washington County

All Washington County rules

Compare Washington County to another location·View the Oregon fire regulations overview

Get notified when Brush Clearance in Washington County, OR changes

We'll email you the moment we detect a change in the code. No spam, unsubscribe anytime.

We'll never sell or share your email. One-click unsubscribe in every email.

See something wrong?

Help us keep this page accurate. If you notice an error or outdated information, let us know.

Brush Clearance in Cities Across Washington County