Key Facts

Clearance distance
100 feet (PRC 4291)
Zone 0 ember zone
0 to 5 ft non-combustible (AB 3074)
Grass height in Zone 2
Max 4 inches
Inspection
Annual by ConFire in WUI/VHFHSZ
Non-compliance
Abatement, lien, $100 to $500 penalties

Summary

Properties in State Responsibility Areas and Very High Fire Hazard Severity Zones across unincorporated Contra Costa must maintain 100 feet of defensible space under Public Resources Code 4291. ConFire conducts annual inspections in the WUI, and non-compliance can trigger abatement, liens, and fines starting at $100 and escalating to misdemeanor charges.

City-specific rules exist: Richmond, Brentwood, Antioch, San Ramon, Pittsburg, and Concord have their own brush clearance rules that differ from Contra Costa County's county-level regulations. If you live in one of those cities, check the city-specific page instead.

(a) A person who owns, leases, controls, operates, or maintains a building or structure in the state responsibility area shall at all times do all of the following:

(1) (A) Maintain defensible space of 100 feet from each side and from the front and rear of the structure, but not beyond the property line, except as provided in subparagraph (B). The amount of fuel modification necessary shall consider the flammability of the structure as affected by building material, building standards, location, and type of vegetation. Fuels shall be maintained and spaced in a condition so that a wildfire would be unlikely to ignite the structure. This subparagraph does not apply to single specimens of trees or other vegetation that are well-pruned and maintained so as to effectively manage fuels and not form a means of rapidly transmitting fire from other nearby vegetation to a structure or from a structure to other nearby vegetation or to interrupt the advance of embers toward a structure. The intensity of fuels management may vary within the 100-foot perimeter of the structure, with more intense fuel reductions being utilized between 5 and 30 feet around the structure, and an ember-resistant zone being required within 5 feet of the structure, based on regulations promulgated by the board, in consultation with the department, to consider the elimination of materials in the ember-resistant zone that would likely be ignited by embers.

(2) Remove that portion of a tree that extends within 10 feet of the outlet of a chimney or stovepipe.

(3) Maintain a tree, shrub, or other plant adjacent to or overhanging a building free of dead or dying wood.

(4) Maintain the roof of a structure free of leaves, needles, or other vegetative materials.

Source: CA Public Resources Code 4291View official code

Full Breakdown

Public Resources Code 4291 and California Government Code 51182 require any person who owns, leases, controls, operates, or maintains an occupied dwelling or structure in or adjacent to an SRA or VHFHSZ to maintain 100 feet of defensible space. Zone 0 (ember-resistant zone, 0–5 feet from structures) is now required under AB 3074 and regulations adopted by the State Board of Forestry: no combustible mulch, plants, fences, or stored items touching the home. Zone 1 (5–30 feet) requires lean, clean, and green: remove dead vegetation, space shrubs, trim tree limbs 10 feet from chimneys and 6 feet from the ground.

Zone 2 (30–100 feet) requires reduced fuel: grass cut to 4 inches, horizontal and vertical shrub spacing, dead material removed. ConFire conducts mandatory annual exterior hazard inspections in designated hazardous fire areas covering Mount Diablo foothills, Lamorinda ridgelines, Morgan Territory, and the Kensington/El Sobrante hills. Non-compliance notices give 30 days to correct; failure to comply leads to contractor abatement with costs placed as a lien on the property plus administrative penalties of $100 to $500. Violations during fire season may be prosecuted as misdemeanors.

Frequently Asked Questions

Does PRC 4291 apply to renters?
Yes. The statute applies to any person who owns, leases, controls, operates, or maintains the property. Owner and tenant share responsibility, though the owner is ultimately liable for the lien.
Are oak trees protected when I clear defensible space?
Native oaks and other protected trees may require a tree-removal permit for whole-tree removal, but routine limbing to 6 feet and removing dead wood for fire safety is allowed without a permit.

Sources & Official References

Other rules in Contra Costa County

All Contra Costa County rules

California rules heatmap·Compare Contra Costa County to another location·View the California fire regulations overview

Get notified when Brush Clearance in Contra Costa County, CA changes

We'll email you the moment we detect a change in the code. No spam, unsubscribe anytime.

We'll never sell or share your email. One-click unsubscribe in every email.

See something wrong?

Help us keep this page accurate. If you notice an error or outdated information, let us know.

Brush Clearance in Cities Across Contra Costa County