Skip to main content
CityRuleLookup

Prince George's County, MD Fire Regulations: Propane Storage (2026)

Some Restrictions
Compiled from the official code textEditor Martyn O'NeillLast verified August 2026

Key Facts

Bulk fence trigger
Tanks over 2,000 gallons water capacity
Fence height required
6-foot industrial-type fence
Residential cylinder limit
2 ICC-DOT cylinders, 2.5 lb each
Customer tank placement
Must be outside of buildings
Enforcement
Fire Chief or authorized representative
Penalty
$100-$1,000 fine (Sec. 11-114)

Summary

Prince George's County keeps liquid petroleum gas storage outside living spaces. Sec. 11-263 requires customer supply tanks to sit outside buildings with Fire Chief-approved valve enclosures, and installations over 2,000 gallons aggregate capacity need a locked, six-foot industrial-type fence. Inside a residential building, LP-gas containers are capped at two small ICC-DOT cylinders of 2.5 pounds water capacity, tied to an approved torch assembly.

These county ordinances apply to unincorporated areas of Prince George's County. Incorporated cities within the county may have their own rules that take precedence over county-level regulations.

(b)Safeguarding of customers' supply tanks. Tanks supplying customers' installations shall be located outside of buildings. All valves and connections thereon shall be safeguarded by an enclosure approved by the Fire Chief or authorized representative. Installations with an aggregate water capacity of greater than two thousand (2,000) gallons shall have the area, which includes the tank and container appurtenances, enclosed with at least six (6) foot high industrial-type fence unless otherwise adequately protected. Gates shall be locked at all times when no responsible person or agent is present.(d)Containers in residential buildings. Liquid petroleum gas containers stored in a building housing residential occupancies shall be limited to two (2) ICC-DOT cylinders with a water capacity not exceeding two and one-half (2 1/2) pounds which shall be part of an approved, self-contained hand torch assembly or similar appliance.

View official code

Official source re-checked September 7, 2026: no newer edition of the code had been published (publisher’s edition: Code of Ordinances: Supplement 2026 Update 2).

Full Breakdown

Sec. 11-263, in Subtitle 11's Fire Prevention Code, regulates liquified petroleum gas from bulk storage plants down to household cylinders. At bulk plants, every space where LP-gas is transferred or stored, including connections to storage tanks, must be segregated with a fence the Fire Chief or an authorized representative approves, and gates must stay locked whenever no responsible person or agent is present. Tanks that supply individual customer installations must sit outside of buildings, with valves and connections protected by an approved enclosure; once an installation's aggregate water capacity passes 2,000 gallons, the tank and its appurtenances must be enclosed by at least a six-foot industrial-type fence unless the Fire Chief accepts another form of protection, and the gate must be kept locked when unattended.

For bulk storage of 2,000 gallons or more in heavily populated or congested areas, Sec. 11-263(c) gives the Fire Chief discretion over individual tank capacity, total storage, distance to property lines, underground storage, fixed fire-suppression systems, and any other protective measure needed. Inside a residential building, storage is far more limited: Sec. 11-263(d) caps LP-gas containers at two ICC-DOT cylinders with a water capacity not exceeding two and one-half pounds each, and only when they are part of an approved, self-contained hand torch assembly or similar appliance, ruling out larger cylinders such as standard 20-pound grill tanks from being stored inside a home.

Violations & Fines

Storing LP-gas outside these limits, leaving a bulk enclosure unfenced or unlocked, or keeping oversized cylinders inside a residence violates Subtitle 11 and is a misdemeanor under Sec. 11-114, punishable by a fine of $100 to $1,000, up to six months in jail, or both, with each day of the violation charged separately. The Fire Chief or an authorized representative inspects and enforces compliance.

Frequently Asked Questions

Can I keep a large propane tank inside my house?
No. Sec. 11-263(b) requires tanks supplying customer installations to sit outside of buildings, with valves and connections enclosed and approved by the Fire Chief, and any installation over 2,000 gallons aggregate water capacity fenced with a locked six-foot industrial-type fence.
What about small propane cylinders indoors?
Sec. 11-263(d) allows liquid petroleum gas containers inside a residential building only if limited to two ICC-DOT cylinders with a water capacity of no more than two and one-half pounds each, and only as part of an approved, self-contained hand torch assembly or similar appliance.
Who decides how a bulk propane site is protected?
Sec. 11-263(c) leaves tank capacity, total storage, distance to property lines, underground storage and fire-suppression requirements for bulk sites of 2,000 gallons or more in populated areas to the Fire Chief's or authorized representative's determination.

Sources & Official References

Other rules in Prince George's County

All Prince George's County rules

Compare Prince George's County to another location·View the Maryland fire regulations overview

Get notified when Propane Storage in Prince George's County, MD changes

We'll email you the moment we detect a change in the code. No spam, unsubscribe anytime.

We'll never sell or share your email. One-click unsubscribe in every email.

See something wrong?

Help us keep this page accurate. If you notice an error or outdated information, let us know.