Key Facts
- Governing section
- El Dorado County Code § 110.16.150
- Applies in snow loads of
- 100 pounds or more
- Regulator riser clearance
- within 12 inches of tank
- Plot plan required
- 3 copies filed with permit
- Appliance placement ban
- below first floor or grade
Summary
In El Dorado County's heavy snow-load areas, every new or reconnected propane installation needs a two-stage regulator system, protected risers, and snow stakes marking the tank, plus a three-copy plot plan filed with the building permit. Appliances cannot be installed below the first floor or below grade.
Facilities in snow-load areas. This subsection shall apply in snow-load areas of 100 pounds or more, to all new liquefied petroleum gas (LPG) installations... Two stage regulator systems shall be installed on all LPG installations... The riser from the yard piping shall be located not more than 12 inches (horizontally) from the walls of the tank... Propane appliances and accessories shall not be permitted in any new installation below the first floor level or below grade, whichever is most restrictive.
Official source re-checked September 7, 2026: no newer edition of the code had been published (publisher’s edition: Code of Ordinances: Supplement 13 Update 4).
Full Breakdown
3 for snow-load areas of 100 pounds or more, covering all new liquefied petroleum gas installations and existing installations reconnected after an unscheduled service interruption. Two-stage regulator systems are mandatory. The first stage regulator installs under the tank's hinged gauge cover with its atmospheric pressure aperture pointed downward, plumbed to the yard piping riser with soft copper tubing so the tank can shift without breaking the line, and that riser must sit within 12 inches of the tank walls. The second stage regulator and riser go under the building eave, braced to the wall about ten inches below the regulator to resist lateral snow and ice loads, and need a protective cover approved by both the gas supplier and the Building Official.
Riser pipes cannot be embedded in concrete; any surrounding concrete must be held back at least one inch. At building permit application for any LPG system, the applicant must submit a three-copy plot plan showing tank location, proposed tank capacity in gallons, yard piping route, riser location, property boundaries, and building outlines and roofline, with the third copy forwardable to the local fire district as an emergency locator map. The tank centerline must be permanently marked with snow stakes at each end, tall enough to show above maximum anticipated snow depth, and maintaining those stakes is the LPG user's responsibility. Propane appliances and accessories cannot be installed below the first floor level or below grade.
Violations & Fines
Installing an LPG system without the required permit, plot plan, or code-compliant regulator and riser setup is enforceable as a building code violation under Section 110.16.020(C): a misdemeanor punishable by up to $1,000.00 and six months in County jail, reducible to an infraction with a maximum $500.00 fine at the discretion of the Building Official or District Attorney. Each day the noncompliant installation continues is a separate offense.
Frequently Asked Questions
Do I need special propane tank rules in El Dorado County's snow zones?
What has to be filed with the building permit for a propane installation?
Can I put propane appliances in my basement?
Sources & Official References
Other rules in El Dorado County
California rules heatmap·Compare El Dorado County to another location·View the California fire regulations overview
See something wrong?
Help us keep this page accurate. If you notice an error or outdated information, let us know.