DeKalb County, GA Hurricane Preparedness: Roof Standards (2026)
Key Facts
- Requirement
- Hurricane-type roof-to-wall connections
- Sheathing
- 7/16-inch plywood or OSB
- Valley flashing
- At least 12 in. either side
- Drip edges
- Required at all roofing edges
- Applies
- Unincorporated DeKalb residential construction
Summary
DeKalb County amends the International Residential Code to require that roof framing on residential construction in the unincorporated county be tied securely to wall framing with hurricane-type connections, alongside 7/16-inch exterior wall sheathing, valley flashing extending at least 12 inches to each side, and drip edges at all roofing edges.
Roof framing shall be tied securely to wall framing, using hurricane type connections. All exterior wall sheathing shall be made of seven-sixteenth ( 7/16 ) plywood or oriented strand board or other approved materials. Metal or self-sealing flashing shall be installed at least twelve (12) inches on either side of roof valleys. Drip edges shall be installed at all roofing edges.
Full Breakdown
Section 7-52(b)(2)(L) is a local amendment layered onto the state-adopted International Residential Code, and it bundles structural requirements into one paragraph. The headline rule is the tie-down: roof framing shall be tied securely to wall framing using hurricane-type connections, so the roof structure is mechanically fastened to the walls rather than simply resting on them. The same paragraph requires all exterior wall sheathing to be seven-sixteenth-inch plywood or oriented strand board, while leaving room for other approved materials, which puts the approval call with the county rather than the builder.
Roof valleys must carry metal or self-sealing flashing installed at least 12 inches on either side of the valley, and drip edges are required at every roofing edge. These amendments govern residential construction in unincorporated DeKalb County only; the incorporated cities inside the county adopt their own residential code amendments, so a builder working across city lines cannot assume the same package applies. Compliance is checked in the field rather than on paper: roof framing installed without the hurricane-type connections fails the frame inspection required under § 7-34(c) and must be corrected before work continues.
Violations & Fines
Roof framing installed without hurricane-type connections to the wall framing fails the frame inspection required under § 7-34(c) and must be corrected before work continues.
Frequently Asked Questions
Does DeKalb County require hurricane straps on new homes?
Is this a state code rule or a local one?
What exterior wall sheathing does DeKalb require?
How far must valley flashing extend?
Sources & Official References
Other rules in DeKalb County
Compare DeKalb County to another location·View the Georgia hurricane preparedness overview
See something wrong?
Help us keep this page accurate. If you notice an error or outdated information, let us know.