Skip to main content
CityRuleLookup

Montgomery County, MD Noise from Specific Sources: HVAC & Mechanical Noise (2026)

Some Restrictions
Compiled from the official code textEditor Martyn O'NeillLast verified September 2026

Key Facts

Property-line limit
60 dBA (55 dBA if tonal)
Applies to
lots under 12,000 sq ft
Pre-1989 units
65 dBA allowance expired 1999
Enforcing agency
Dept. of Environmental Protection
Civil penalty
$500 first, $750 repeat offense

Summary

Outdoor heat pumps and A/C units on small residential lots in Montgomery County must meet a strict 60 dBA property-line limit, enforced under a dedicated executive regulation, not the general noise code.

These county ordinances apply to unincorporated areas of Montgomery County. Incorporated cities within the county may have their own rules that take precedence over county-level regulations.

The maximum permissible sound level at the property line for the outdoor unit of any heat pump or air conditioner located on residential lots less than 12,000 square feet in area must not exceed 60 dBA. If the sound is determined to be a tonal noise as defined in 31B.00.03.03, the maximum permissible sound level at the nearest property line must not exceed 55 dBA.

View official code

Official source re-checked September 7, 2026: no newer edition of the code had been published (publisher’s edition: 2026 S-90: Montgomery County Code contains legislation effective through May 7, 2026 | Zoning Updated Effective: April 13, 2026 | COMCOR Regulations effective as of July 1, 2026).

Full Breakdown

COMCOR 31B.00.03 sets a hard cap on outdoor heat pump and air conditioner noise for houses on lots under 12,000 square feet: 60 dBA at the property line, dropping to 55 dBA if the unit produces a tonal whine or hum. Units made before July 1, 1989 got a temporary 65/60 dBA allowance that expired in 1999. It doesn't cover non-residential buildings, apartments over 30 feet tall, or condos where the unit and the affected neighbor share the same building. Everything else defaults to the county's general 65/55 dBA noise-area limits under Sec. 31B-5.

Violations & Fines

Exceeding the property-line limit is a violation of Sec. 31B-5(b)(2) and a Class A civil violation: up to $500 for a first offense, $750 for a repeat one, or a criminal fine up to $1,000.

Frequently Asked Questions

Does this apply to every AC unit in the county?
No. It only covers outdoor heat pumps/AC on residential lots under 12,000 sq ft. Larger apartment buildings, non-residential buildings, and same-building condo setups fall under the general 65/55 dBA noise limits instead.
Can I get an exemption if my unit can't comply?
Yes, under 31B.00.03.05 an owner may apply for a Special Exemption at least 28 days before installation; neighbors get mailed notice and one week to respond in writing.

Sources & Official References

Other rules in Montgomery County

All Montgomery County rules

Compare Montgomery County to another location·View the Maryland noise from specific sources overview

Get notified when HVAC & Mechanical Noise in Montgomery County, MD changes

We'll email you the moment we detect a change in the code. No spam, unsubscribe anytime.

We'll never sell or share your email. One-click unsubscribe in every email.

See something wrong?

Help us keep this page accurate. If you notice an error or outdated information, let us know.

HVAC & Mechanical Noise in Cities Across Montgomery County