Key Facts

IL cap below 75 cps
70 decibels
IG cap below 75 cps
73 decibels
IL cap above 4,800 cps
30 decibels
Measurement point
Property line (district boundary for IG)
Non-industrial property standard
Compared to ambient street/traffic noise
Violation classification
Misdemeanor under Ch. 63-1209, Laws of Florida

Summary

Charlotte County sets a hard decibel ceiling for industrial property under Code Sec. 3-9-75(g)(3), ranging from 70 decibels in IL districts and 73 in IG districts below 75 cycles per second down to just 30 and 33 decibels above 4,800 cycles, measured at the property line.

These county ordinances apply to unincorporated areas of Charlotte County. Incorporated cities within the county may have their own rules that take precedence over county-level regulations.

(3)Noise. The permitted level of noise or sound emission shall not exceed the values in any octave band of frequency in the following table. Sound pressure levels shall be measured with a sound level meter and an octave band analyzer that conform to the specifications published by the American Standards Association.a.For industrially zoned property: Maximum Sound Pressure Level in Decibels (Decibel = 0.0002 dynes per square centimeter) Cycles per sound IL IG Below 75: 70 73; 75-150: 65 68; 150-300: 57 60; 300-600: 50 53; 600-1,200: 44 47; 1,200-2,400: 38 41; 2,400-4,800: 32 35; 4,800-over: 30 33.b.For all other property: It shall be unlawful for any person to permit the level of noise or sound emission to exceed at any time the average noise level prevailing for the same hour, as generated by street and traffic activity.

Full Breakdown

Sec. 3-9-75(g)(3)a lays out a full octave-band table for industrially zoned property. Below 75 cycles per second the cap is 70 decibels in IL (light industrial) districts and 73 decibels in IG (general industrial) districts; the ceiling steps down as frequency rises, to 65/68 decibels at 75 to 150 cycles, 57/60 at 150 to 300, 50/53 at 300 to 600, 44/47 at 600 to 1,200, 38/41 at 1,200 to 2,400, 32/35 at 2,400 to 4,800, and finally just 30 decibels (IL) or 33 decibels (IG) above 4,800 cycles.

Measurements have to be taken with a sound level meter and octave band analyzer built to American Standards Association specifications, and under subsection (g), the reading point is the property line for every zoning district except IG, where it is instead measured at the district boundary. Property that is not zoned industrial gets a different, non-numeric standard under (g)(3)b: it is unlawful to let noise exceed the average noise level prevailing for that same hour, as generated by street and traffic activity, measured with the same type of sound level meter.

The industrial performance standards apply on top of whatever other governmental noise rules exist, and before an industrial use can be permitted, the applicant has to submit machinery and process specifications to the zoning official and acknowledge in writing an understanding of, and agreement to conform with, these performance standards.

Violations & Fines

Sec. 3-9-75(i) puts enforcement in the hands of the zoning official, who investigates any alleged violation of the industrial performance standards. Where the zoning official finds reasonable evidence that a violation exists, the violation is treated as a misdemeanor under Chapter 63-1209, Laws of Florida, rather than handled as a simple civil code enforcement citation.

Frequently Asked Questions

What is the maximum noise level for industrial property in Charlotte County?
Sec. 3-9-75(g)(3) sets an octave-band table: below 75 cycles per second the cap is 70 decibels in IL districts and 73 decibels in IG districts, and the ceiling drops as frequency rises, down to just 30 or 33 decibels above 4,800 cycles per second.
How does the county measure industrial noise?
With a sound level meter and octave band analyzer built to American Standards Association specifications, read at the property line for every district except IG property, which is measured at the district boundary instead, per Sec. 3-9-75(g).
Is there a fixed decibel limit for non-industrial property?
No. Sec. 3-9-75(g)(3)b instead bars noise that exceeds the average noise level prevailing for that hour as generated by street and traffic activity, measured with the same type of sound level meter used for industrial property.
What happens if an industrial noise violation is confirmed?
Sec. 3-9-75(i) has the zoning official investigate alleged violations, and if reasonable evidence of a violation is found, it is treated as a misdemeanor under Chapter 63-1209, Laws of Florida, rather than a routine civil citation.

Sources & Official References

Other rules in Charlotte County

All Charlotte County rules

Florida rules heatmap·Compare Charlotte County to another location·View the Florida noise ordinances overview

Get notified when Decibel Limits in Charlotte County, FL changes

We'll email you the moment we detect a change in the code. No spam, unsubscribe anytime.

We'll never sell or share your email. One-click unsubscribe in every email.

See something wrong?

Help us keep this page accurate. If you notice an error or outdated information, let us know.