St. Tammany Parish, LA Outdoor Lighting: Dark Sky Rules (2026)

Some Restrictions
Compiled from the official code textEditor Martyn O'NeillLast verified September 2026

Key Facts

Full cutoff required above
3,000 lumens (non-residential)
Max mounting height (>3,000 lumens)
35 feet
Vital building exterior cap
5 footcandles
Loading/ATM footcandle cap
20 footcandles
SF/2-family aim limit (<=1,500 lumens)
35 degrees from straight down
Athletic field light curfew
1 hour after event ends

Summary

Unincorporated St. Tammany Parish requires full cutoff, shielded fixtures for most outdoor lighting and caps footcandle spillover at property lines under UDC Section 600-2.1. The Department of Planning and Development reviews a photometric plan and luminaire schedule before issuing a commercial lighting permit, and the section's stated purpose is to eliminate glare and minimize light trespass onto neighboring land.

These county ordinances apply to unincorporated areas of St. Tammany Parish. Incorporated cities within the county may have their own rules that take precedence over county-level regulations.

A.Statement of Need and Purpose. Good outdoor lighting at night benefits everyone. It increases safety, enhances the parish's nighttime character, and helps provide security. C.Design Requirements.1.For uses other than single-family or 2-family residential:a.Luminaire design. Any luminaire with a lamp or lamps rated at an average of more than 3,000 lumens shall be a full cut-off type fixture.b.Luminaire height.i.Any luminaire with a lamp rated at an average of less than 3,000 lumens may be mounted at any height.ii.Any luminaire with a lamp rated an average of more than 3,000 lumens may be mounted up to a height of 35 feet.

View official code

Official source re-checked September 7, 2026: no newer edition of the code had been published (publisher’s edition: Code of Ordinances: Supplement 12 Update 2).

Full Breakdown

1(A) declares that good outdoor lighting benefits everyone by increasing safety and security, and the section backs that purpose with fixture design rules in subsection C. For commercial, multi-family and other non-single or two-family uses, any fixture averaging more than 3,000 lumens must be a full cutoff design and cannot mount higher than 35 feet, while dimmer fixtures under 3,000 lumens carry no height cap; the code deems specific lamp wattages, such as a 200-watt incandescent bulb or a 30-watt high-pressure sodium lamp, to cross the 3,000-lumen line.

A photometric plan and luminaire schedule must accompany any commercial lighting permit application, showing footcandle readings on a site grid; the standards table caps active entrances and vital building exteriors at 5 footcandles, inactive entrances and building surrounds at 1 footcandle, loading platforms and ATMs at 20 footcandles, and service station pump islands at 20 footcandles, all measured 3 feet above grade. Single-family and two-family lots follow a lighter standard in subsection C(3): fixtures emitting 1,500 lumens or less must aim no higher than 35 degrees above straight down when visible from an adjoining residential lot or public road, fixtures between 1,500 and 3,000 lumens are capped at 3,000K color temperature, and anything over 3,000 lumens must be fully shielded. 5 maintained footcandle at an adjoining residential property line, and such fields must go dark within one hour after an event ends.

Violations & Fines

Section 600-2.1(F) separately bans laser source light and searchlights used for outdoor advertising or entertainment, except for government or emergency use, prohibits any fixture that could be mistaken for a traffic control device, and bars illuminated billboards, other than those next to interstate highways, between 11:00 p.m. and sunrise. The Department of Planning and Development enforces the section through the same lighting permit process used for other construction, and a change request and department approval are required before any noncompliant fixture or lamp substitution is installed.

Frequently Asked Questions

Does St. Tammany Parish require shielded outdoor lighting?
Yes. UDC Section 600-2.1(C)(1)(a) requires any non-residential luminaire averaging more than 3,000 lumens to be a full cutoff fixture, and the section's stated purpose is to eliminate glare and minimize light trespass onto neighboring property in every zoning district.
Are homeowners subject to the same lighting rules as businesses?
No. Single-family and two-family lots follow the lighter standard in Section 600-2.1(C)(3): fixtures of 1,500 lumens or less must aim no higher than 35 degrees above straight down toward neighboring property, and only fixtures over 3,000 lumens must be fully shielded.
Is there a limit on how bright outdoor lighting can be at the property line?
Yes. The footcandle table in Section 600-2.1(C)(1)(c) caps most building exteriors and active entrances at 5 footcandles and loading platforms or ATMs at 20 footcandles, measured 3 feet above ground with the meter held horizontal.

Sources & Official References

Other rules in St. Tammany Parish

All St. Tammany Parish rules

Compare St. Tammany Parish to another location·View the Louisiana outdoor lighting overview

Get notified when Dark Sky Rules in St. Tammany Parish, LA changes

We'll email you the moment we detect a change in the code. No spam, unsubscribe anytime.

We'll never sell or share your email. One-click unsubscribe in every email.

See something wrong?

Help us keep this page accurate. If you notice an error or outdated information, let us know.