Key Facts

Governing section
Zoning Ordinance § 7.05.02.B
Fixture type required
Full cutoff, downward and inward aimed
Illumination cap at lot line
0.25 foot-candles above background
Max mounting height
25 feet
Security exemption
Exempt from 11 p.m.–7 a.m. shutoff
Color temperature limit
3000K or less

Summary

Any outdoor security light installed in Loudoun County must be full cutoff, aimed downward and inward, and capped at 0.25 foot-candles of spillover measured at the property line, under Zoning Ordinance Section 7.05.02.B. Security fixtures get one carve-out other lighting doesn't: the Zoning Administrator can exempt them from the countywide rule that all exterior lighting shut off between 11 p.m. and 7 a.m.

These county ordinances apply to unincorporated areas of Loudoun County. Incorporated cities within the county may have their own rules that take precedence over county-level regulations.

Lighting fixtures must be full cutoff so that the emitted light is not projected above the horizontal plane of the shield, or bulb enclosure, and the bulb is recessed or level with the lowest portion of the lighting shield. ... Lighting fixtures must be aimed downward and inward to direct light towards the interior of the property. ... Lighting must not cause illumination in excess of 0.25 foot-candles above background light levels measured at the lot line of any adjacent lot or road right-of-way.

Full Breakdown

02 is the county's general exterior-lighting standard, applying to new and replacement fixtures on essentially every use type, aside from residential accessory lighting and a handful of exemptions such as holiday lights, pool lighting, and motion sensors that cut off within 5 minutes. Under subsection B, every regulated fixture, including lighting installed specifically for security, must be full cutoff, meaning the light source sits recessed behind or level with the shield so no light is emitted above the horizontal plane, verified by manufacturer certification or an International Dark-Sky Association Fixture Seal of Approval.

Pole-mounted fixtures also need side shielding below the bulb except at driveways and intersections, and every fixture must be aimed downward and inward toward the interior of the property rather than toward neighboring lots or the street. 25 foot-candles above background light levels at the lot line of any adjacent parcel or road right-of-way, documented on a photometric plan submitted with the permit application. Maximum mounting height is 25 feet unless a use-specific standard in Chapter 4 sets something different, and all new luminaires must be rated 3000K or lower correlated color temperature. 25 foot-candle standards.

Violations & Fines

Unshielded, upward-aimed, or over-bright security lighting is a Zoning Ordinance violation enforced under Section 10.13. The Zoning Administrator can require a corrected photometric plan and fixture retrofit after notice and a cure period; an uncorrected violation carries a civil penalty of $200 for the first offense and $500 per day after, capped at $5,000, with a Special Exception under Sections 10.11.01 and 10.11.09 the only path to a fixture that doesn't meet the standard.

Frequently Asked Questions

Can I leave a security light on all night in Loudoun County?
Yes. Section 7.05.02.B.7.d exempts exterior lighting necessary for security purposes, as determined by the Zoning Administrator, from the general rule requiring most exterior lighting to shut off between 11:00 p.m. and 7:00 a.m. The fixture still has to meet the full-cutoff, downward-aim, and 0.25 foot-candle standards that apply at all times.
How bright can a security light be at my property line?
No more than 0.25 foot-candles above background light levels, measured at the lot line of any adjacent lot or road right-of-way, per Section 7.05.02.B.3. Anyone installing new outdoor lighting must submit a photometric plan documenting that the fixture meets this ceiling.
Does a security light have to point straight down?
It has to be aimed downward and inward toward the interior of the property, and be full cutoff so no light projects above the horizontal plane of the shield. Pole-mounted security lights also need side shielding below the bulb, except right at driveways and travel-way intersections.
What happens if my security lighting doesn't meet these standards?
It's a Zoning Ordinance violation under Section 10.13. Expect a notice from the Zoning Administrator with a deadline to fix the fixture; if it's not corrected, civil penalties start at $200 for the first offense and rise to $500 per day, capped at $5,000 before criminal referral.

Sources & Official References

Other rules in Loudoun County

All Loudoun County rules

Compare Loudoun County to another location·View the Virginia outdoor lighting overview

Get notified when Light Trespass & Shielding in Loudoun County, VA changes

We'll email you the moment we detect a change in the code. No spam, unsubscribe anytime.

We'll never sell or share your email. One-click unsubscribe in every email.

See something wrong?

Help us keep this page accurate. If you notice an error or outdated information, let us know.