Key Facts

Minimum heat
68F in habitable rooms (PMC 602.2)
Max cooling temp
85F ceiling (PMC 603.7(A))
Cooling standard
15F cooler than outside temp
Hot outside defense
85F ok if outside exceeds 110F
Unsafe-structure duty
Repair plan + housing within 2 days

Summary

Austin's Property Maintenance Code sets hard temperature floors and ceilings for rented housing: residential heating must reach 68F and, for commercial structures with dwelling or sleeping units, air conditioning must keep habitable rooms at least 15 degrees cooler than outside, never above 85F. Space heaters and unvented fuel-burning heaters cannot substitute for a working system.

602.2 Residential occupancies. Heating facilities that are capable of maintaining a room temperature of 68F (20C) in habitable spaces, bathrooms, and toilet rooms are required in each dwelling unit. Cooking appliances and unvented fuel-burning space heaters cannot be used to meet or maintain the room temperature required by this section... 603.7 Cooling Facilities Required. (A)An owner shall:(i)Provide and maintain, in operating condition, refrigerated air equipment capable of maintaining a room temperature of at least 15 degrees cooler than the outside temperature, but in no event higher than 85F in each habitable room...(C)It is a defense to prosecution under this paragraph that at least one habitable room is 85F, if the outside temperature is over 110F.

Full Breakdown

2 requires heating facilities capable of maintaining 68F (20C) in habitable spaces, bathrooms, and toilet rooms of every dwelling unit, and specifically bars cooking appliances and unvented fuel-burning space heaters from being used to meet that requirement; a portable electric space heater is allowed only "on a temporary basis" and only per the manufacturer's specifications. 3 extends the 68F floor to occupied commercial structures containing dwelling or sleeping units. 7(A) requires owners to provide and maintain refrigerated air conditioning capable of keeping each habitable room at least 15 degrees cooler than the outside temperature, but never above 85F, and to keep the AC system, covers, panels, conduits, and disconnects properly attached and operating.

7(B) fixes how that temperature is measured: three feet above the floor near the center of the room and two feet inward from the center of each exterior wall. 7(C) gives owners a narrow defense: if the outside temperature exceeds 110F, a habitable room registering 85F is not a violation. 3 require the owner to submit a repair action plan and provide the displaced occupants with approved alternate accommodations within two days of notice. These duties sit inside the broader Property Maintenance Code framework enforced by the Building and Standards Commission (City Code Ch. 25-12, Art. 9), which is separate from the registration duties imposed on Austin rental owners under City Code Chapter 4-14.

Violations & Fines

An owner who fails to maintain required heat or cooling is subject to enforcement by Austin Code Compliance and referral to the Building and Standards Commission, which can order repairs and relocation accommodations; where a structure is found unsafe, the owner must submit a repair plan and arrange approved alternate housing for occupants within two days of notice under Sections 602.2 and 604.3.

Frequently Asked Questions

What temperature is a landlord required to maintain in an Austin rental?
Section 602.2 of the Property Maintenance Code requires heating capable of maintaining at least 68F in habitable spaces, bathrooms, and toilet rooms. Cooking appliances and unvented fuel-burning space heaters cannot be used to satisfy this requirement.
Is there a maximum indoor temperature Austin landlords must meet in summer?
Yes. Section 603.7(A) requires owners to maintain refrigerated air conditioning that keeps each habitable room at least 15 degrees cooler than outside, and never above 85F, measured three feet above the floor near the room's center.
Can a landlord skip the 85F cooling cap during a heat wave?
Only in a narrow case. Section 603.7(C) provides a defense to prosecution if at least one habitable room reaches 85F and the outside temperature is over 110F; otherwise the 85F ceiling and 15-degree differential still apply.

Sources & Official References

Other rules in Austin

All Austin rules

Texas rules heatmap·Compare Austin to another location·View the Texas rental property rules overview

Get notified when Repairs & Habitability in Austin, TX changes

We'll email you the moment we detect a change in the code. No spam, unsubscribe anytime.

We'll never sell or share your email. One-click unsubscribe in every email.

See something wrong?

Help us keep this page accurate. If you notice an error or outdated information, let us know.