Takoma Park residential pools must comply with Montgomery County safety standards based on the International Swimming Pool and Spa Code. Requirements include anti-entrapment drain covers meeting Virginia Graeme Baker Act standards, ground-fault circuit interrupter protection for electrical equipment, and proper chemical storage. Pools must maintain compliant water clarity and circulation systems at all times.
Residential pools in Takoma Park must meet the safety standards enforced by Montgomery County Department of Permitting Services. All pool and spa drains must have anti-entrapment covers compliant with the Virginia Graeme Baker Pool and Spa Safety Act (federal law P.L. 110-140). Single main drain pools must have a secondary anti-entrapment system such as a safety vacuum release system or gravity drainage system. All electrical equipment serving the pool must be protected by ground-fault circuit interrupters and installed by a licensed electrician. Pool wiring and bonding must meet the National Electrical Code. Chemical storage for pool treatment must be in a ventilated, locked area inaccessible to children. Pool water must maintain adequate clarity so that the main drain is visible from the pool deck. Circulation and filtration systems must operate to maintain water quality. Diving boards on residential pools require minimum water depth of 7.5 feet in the diving area. Montgomery County does not mandate residential pool alarms county-wide, but alarms on doors opening to pool areas can satisfy barrier requirements. Contact Montgomery County DPS at 240-777-0311 for inspection scheduling.
Safety violations found during inspection may result in orders to cease pool use until corrections are made. Electrical violations are treated as immediate hazards. Operating a pool with non-compliant drain covers violates federal law. Fines are assessed through Montgomery County code enforcement for ongoing noncompliance.
Takoma Park, MD
Takoma Park sets residential decibel limits at 65 dBA daytime and 55 dBA nighttime under Ordinance 2002-35. If ambient noise already exceeds these thresholds...
Takoma Park, MD
Takoma Park adopts Montgomery County construction noise standards (MoCo Code 31B-6) by reference. Weekday construction is allowed 7 AM to 5 PM at up to 75 dB...
Takoma Park, MD
Outdoor music in Takoma Park must comply with 65 dBA daytime and 55 dBA nighttime limits. Events with amplified outdoor music require a temporary waiver requ...
Takoma Park, MD
Under Chapter 14.12 Section 9, no person may allow a dog or other animal to persistently, habitually, or continuously bark, howl, or yelp causing a noise dis...
Takoma Park, MD
Industrial and commercial noise in Takoma Park must meet the same residential decibel limits as all other sources: 65 dBA daytime and 55 dBA nighttime at the...
Takoma Park, MD
Takoma Park has among the strictest leaf blower rules in the DC metro. The city noise ordinance (Ch. 14.12, Sec. 8) caps all leaf blowers at 70 dBA at 50 fee...
Side-by-side rule comparisons with other cities in Montgomery County.
See how other cities in Montgomery County handle safety rules.
See how Takoma Park's safety rules rules stack up against other locations.
Quick Compare
Help us keep this page accurate. If you notice an error or outdated information, let us know.