Key Facts

Applies to
New or fully renovated mid-rise buildings
Requirement
Simultaneous unlock from fire command center
Fail-safe
Auto-unlock on power loss or alarm
Hardware standard
State Fire Marshal listed, permit required

Summary

In unincorporated San Diego County, new or fully renovated mid-rise buildings must wire stairway door locks to release automatically from the fire command center, and locking hardware needs State Fire Marshal listing and fire official approval before installation.

City-specific rules exist: Oceanside has its own door locking hardware rules that differ from San Diego County's county-level regulations. If you live in Oceanside, check the city-specific page instead.

Sec. 324.1.9.5 Locking of stairway doors. All stairway doors that are locked to prohibit access from the interior of the stairway shall have the capability of being unlocked simultaneously, without unlatching, upon a signal from the fire command center. Upon failure of normal electrical service or activation of any fire alarm, the locking mechanism shall automatically retract to the unlocked position. Hardware for locking stairway vestibule doors shall be State Fire Marshal listed and approved by the fire code official by permit before installation.

View official code

Official source re-checked September 7, 2026: no newer edition of the code had been published (publisher’s edition: 2026 S-141: Administrative: Current through Ord. No. 11007 (N.S.), effective 7-10-26 | Regulatory: Current through Ord. No. 11008 (N.S.), effective 7-24-26).

Full Breakdown

San Diego County Code § 96.1.324, the county's amendment to the California Fire Code, requires stairway doors in new or completely renovated mid-rise buildings that lock from the interior to unlock simultaneously on a signal from the fire command center, and to retract automatically on power failure or fire alarm activation. Locking hardware on stairway vestibule doors must carry State Fire Marshal listing and be approved by the fire code official by permit before installation. Doors between the vestibule and the stairway shaft itself cannot be locked. The rule applies only to mid-rise construction in the unincorporated county: incorporated cities like San Diego set their own fire code amendments.

Violations & Fines

Noncompliant locking hardware fails plan check and final inspection by the fire code official; buildings cannot obtain occupancy approval until stairway door hardware meets this section.

Frequently Asked Questions

Does this rule apply to my house?
No. It only covers stairway doors in new or fully renovated mid-rise buildings in unincorporated San Diego County; single-family homes aren't mid-rise construction and aren't covered by this section.
Can a stairway door ever be locked from inside?
Yes, but the lock must release automatically from the fire command center on signal, and unlock on its own if power fails or a fire alarm activates.

Sources & Official References

Other rules in San Diego County

All San Diego County rules

California rules heatmap·Compare San Diego County to another location·View the California building safety overview

Get notified when Door Locking Hardware in San Diego County, CA changes

We'll email you the moment we detect a change in the code. No spam, unsubscribe anytime.

We'll never sell or share your email. One-click unsubscribe in every email.

See something wrong?

Help us keep this page accurate. If you notice an error or outdated information, let us know.

Door Locking Hardware in Cities Across San Diego County