Key Facts

Adopted code
International Plumbing Code, 2024 Edition
Required license
TSBPE Responsible Master Plumber
Sewer depth
Minimum 6 inches below grade
Roof vent clearance
At least 6 inches above roof
Appeals body
Killeen Board of Adjustment

Summary

Killeen enforces the 2024 International Plumbing Code under Code Section 8-240, with a state-licensed master plumber required before the city issues a plumbing permit. Local amendments set a minimum 6-inch burial depth for building sewers and a 6-inch minimum clearance for roof vent pipes above the roofline.

There is hereby adopted by the city the International Plumbing Code, 2024 Edition, together with Appendices B (Rates of Rainfall for Various Cities, C (Structural Safety), D (Degree Day and Design Temperatures, and E (Sizing of Water Pipe System) and amendments... ..."305.4.1 Building Sewers. Building sewers that connect to private sewage systems shall be a minimum of 6 inches below finished grade at the point of septic tank connection. Building sewers shall be a minimum of 6 inches below grade." ..."903.1.1 Roof extension. Open vent pipes that extend through a roof shall be terminated at least 6 inches (152 mm) above the roof."

View official code

Official source re-checked September 7, 2026: no newer edition of the code had been published (publisher’s edition: Code of Ordinances: Supplement 38 Update 1).

Full Breakdown

Section 8-240 adopts the International Plumbing Code, 2024 Edition, together with its Appendices B, C, D and E, as the plumbing code enforced citywide, administered by the Killeen Building Inspections Division. 1. Two numeric local amendments narrow the base IPC standards: Section 8-241(5) requires building sewers connecting to a private sewage system to sit a minimum of six inches below finished grade at the septic tank connection and six inches below grade generally, and Section 8-241(6) requires open vent pipes extending through a roof to terminate at least six inches above the roof surface.

As with the other adopted construction codes, no plumbing inspection may occur for new commercial or residential construction unless the jobsite has a properly sized trash receptacle, a posted address number visible from the street, and a construction worker toilet facility, and work that fails an inspection must be resubmitted with a reinspection fee paid before the next inspection. Starting plumbing work before the permit is issued doubles the eventual permit fee owed under Section 8-11(b).

Violations & Fines

Plumbing work performed without a permit, without a Texas-licensed Responsible Master Plumber, or that fails to meet the adopted IPC and its local sewer-depth and vent-clearance amendments is enforced under Section 1-8's general penalty, up to $2,000 for continuing violations, with each day of noncompliance a separate offense.

Frequently Asked Questions

Who is licensed to pull a plumbing permit in Killeen?
Only a person who is, or a company that employs, a Responsible Master Plumber licensed by the Texas State Board of Plumbing Examiners can register as a plumbing contractor and obtain permits under Chapter 8's contractor article, alongside Section 8-240's adoption of the 2024 International Plumbing Code.
How deep must a sewer line be buried in Killeen?
Section 8-241(5) requires building sewers connecting to a private sewage system to run a minimum of six inches below finished grade at the septic tank connection, and building sewers generally must stay at least six inches below grade throughout their run.
How far must a plumbing vent stick out above my roof?
Section 8-241(6) amends IPC Section 903.1.1 to require open vent pipes extending through a roof to terminate at least six inches above the roof surface, a local reduction from the code's unmodified clearance requirement.

Sources & Official References

Other rules in Killeen

All Killeen rules

Texas rules heatmap·Compare Killeen to another location·View the Texas building safety overview

Get notified when Plumbing Permits in Killeen, TX changes

We'll email you the moment we detect a change in the code. No spam, unsubscribe anytime.

We'll never sell or share your email. One-click unsubscribe in every email.

See something wrong?

Help us keep this page accurate. If you notice an error or outdated information, let us know.