Skip to main content
CityRuleLookup

Jackson County, MS Building Setbacks & Zoning: Structure Height Limits (2026)

Some Restrictions
Compiled from the official code textEditor Martyn O'NeillLast verified September 2026

Key Facts

R-1 height limit
35 ft from BFE
R-1 total height cap
45 ft from ground
Height-exempt features
antennas, chimneys, spires, towers
Roof overhang projection allowance
3 ft
Governing table
Zoning Ordinance Table 5-3.4

Summary

In the R-1 Single-Family Residential district, Jackson County caps a main structure at 35 feet above the designated Base Flood Elevation, or 45 feet total height measured from the ground. Height rules exempt certain roof-level features like antennas and chimneys from that limit countywide.

These county ordinances apply to unincorporated areas of Jackson County. Incorporated cities within the county may have their own rules that take precedence over county-level regulations.

D. Height Limit – Maximum allowable height of structures. See Figure to the right. Main Structure 35 ft. from designated Base Flood Elevation (BFE) 45 ft. total height from ground ... Section 4.02.07. Exceptions to Height Regulations. The height regulations contained in the District Regulations of this Ordinance do not apply to poles spires, belfries, cupolas, elevators, antennas, water tanks, ventilation chimneys, masts, towers, or other appurtenances usually required to be placed above the roof level and not intended for human occupancy. ... Section 4.02.08. Roof Overhangs or Appurtenances. Roof overhangs or appurtenances, not on the ground, may project from the outside wall of a residence no more than three (3) feet, and are not considered as part of the setback.

View official code

Official source re-checked September 8, 2026: the cited page had not changed since it was quoted.

Full Breakdown

Table 5-3.4 of the Jackson County Zoning Ordinance sets the R-1 Single-Family Residential District's height limit at 35 feet measured from the designated Base Flood Elevation (BFE), with a hard ceiling of 45 feet total height from the ground. That BFE-based measurement reflects Jackson County's coastal, post-Katrina building requirements, where finished floor heights are tied to FEMA base flood elevations rather than natural grade alone, so the effective limit on a given lot depends on how high the BFE sits above existing ground.

Section 4.02.07 carves out an exception that applies to every district's height regulations, not just R-1: the height limit doesn't apply to poles, spires, belfries, cupolas, elevators, antennas, water tanks, ventilation chimneys, masts, towers, or similar rooftop appurtenances that aren't intended for human occupancy, so a chimney or antenna above the 45-foot line doesn't itself create a violation. Section 4.02.08 adds a separate horizontal allowance: roof overhangs or other appurtenances not resting on the ground can project up to 3 feet from the outside wall of a residence without counting against the required setback, though that provision governs setback encroachment, not height.

Because § 4.01.04 makes each district's dimensional table (Tables 5-3.1 through 5-3.22) the minimum regulation for that district, R-1's 35-foot BFE and 45-foot ground-height figures apply only inside the R-1 boundary; every other residential district, R-1A, R-1B, R-2 through R-5, carries its own height figures in its own table, so a parcel's exact limit has to be confirmed against its actual zoning classification before design begins.

Violations & Fines

Building above the district's height limit is a zoning violation under § 9.5: a misdemeanor carrying a fine up to $500, plus $100 for each day a knowing, willful violation continues after conviction. The Planning Department can require the excess height be removed or brought into compliance, and the county may pursue the matter as a public nuisance.

Frequently Asked Questions

How tall can I build a house in Jackson County's R-1 district?
Table 5-3.4 caps the R-1 main structure at 35 feet measured from the designated Base Flood Elevation, with an overall ceiling of 45 feet total height from the ground. Because Jackson County is coastal, the BFE-based figure usually controls on a flood-zone lot rather than the flat 45-foot number.
Do rooftop items like antennas count toward the height limit?
No. Section 4.02.07 exempts poles, spires, belfries, cupolas, elevators, antennas, water tanks, ventilation chimneys, masts, towers and similar rooftop appurtenances not intended for human occupancy from the district height regulations, in every zoning district countywide.
Why is the height measured from Base Flood Elevation instead of the ground?
Because Jackson County sits on the Gulf Coast and building elevations are tied to flood-zone requirements; Table 5-3.4 measures the R-1 height limit from the designated BFE first, then caps total height from natural ground at 45 feet as a backstop.
Does a roof overhang count against my setback in Jackson County?
Not for height purposes, but it does get a separate allowance. Section 4.02.08 lets a roof overhang or similar appurtenance project up to 3 feet from the outside wall of a residence without counting as part of the required setback, though it still can't push past the district's overall height limit.

Sources & Official References

Other rules in Jackson County

All Jackson County rules

Compare Jackson County to another location·View the Mississippi building setbacks & zoning overview

Get notified when Structure Height Limits in Jackson County, MS changes

We'll email you the moment we detect a change in the code. No spam, unsubscribe anytime.

We'll never sell or share your email. One-click unsubscribe in every email.

See something wrong?

Help us keep this page accurate. If you notice an error or outdated information, let us know.