St. Tammany Parish, LA Building Setbacks & Zoning: Structure Height Limits (2026)

Some Restrictions
Compiled from the official code textEditor Martyn O'NeillLast verified September 2026

Key Facts

Single-family districts (E, R-1, R-2, L-1, L-2, S-1, S-2)
35 feet above natural grade
Two-family (TF) district
45 feet above natural grade
M-M / M-H multi-family (>100 ft from SF zoning)
60 feet above natural grade
M-M / M-H within 100 ft of single-family zoning
35 feet above natural grade
Permit appeal deadline
30 days to Board of Adjustment

Summary

In unincorporated St. Tammany Parish, the Unified Development Code caps residential structures at 35 feet above natural grade in every single-family zoning district, from the 7-acre E Estate District down to the S-1 and S-2 Suburban Districts. Two-family (TF) lots may build to 45 feet, and multi-family districts reach 45 to 60 feet depending on distance from single-family zoning. The Department of Planning and Development enforces the cap through building permit review.

These county ordinances apply to unincorporated areas of St. Tammany Parish. Incorporated cities within the county may have their own rules that take precedence over county-level regulations.

Height regulations. No building or dwelling for residential or business purposes shall exceed 35 feet in height above the natural grade of the property at the location of the structure as established in this UDC.

View official code

Official source re-checked September 7, 2026: no newer edition of the code had been published (publisher’s edition: Code of Ordinances: Supplement 12 Update 2).

Full Breakdown

2 sets the height ceiling for St. Tammany's seven single-family residential districts: E Estate, R-1 and R-2 Rural Residential, L-1 and L-2 Large Lot, and S-1 and S-2 Suburban Residential. Each district's site and structure provisions repeat the same 35-foot cap measured above natural grade, and some districts, such as E Estate and R-1, also measure the limit against base flood elevation, whichever is higher, so a lot with a high base flood elevation cannot use extra fill height to gain additional stories. 3(A)(4)(h), is allowed an extra 10 feet, up to 45 feet, reflecting the district's greater density.

4(B)(4)(g) and (C)(4)(g), but only for buildings set back more than 100 feet from a single-family zoned lot; within that 100-foot buffer, the same sections cut the limit to 35 feet to protect adjacent single-family neighborhoods from an abrupt jump in scale. Height is checked as part of the building permit process under Section 300-2, which requires construction documents showing the structure's dimensions before the Department of Permits and Inspections will issue a permit; the director can reject an application that does not conform. An applicant who wants to exceed the applicable height limit must seek a variance from the Board of Adjustment rather than build first and ask forgiveness.

Violations & Fines

Building beyond the applicable height cap without an approved variance is a UDC violation the Director of Permits and Inspections can catch at plan review or field inspection; noncompliant plans are rejected under Section 300-2(F), and a permit already issued can be suspended or revoked under Section 300-2(J) if it was issued on inaccurate information. An applicant denied a permit, or ordered to correct an over-height structure, may appeal to the Board of Adjustment within 30 days under Section 200-3.10(C)(2).

Frequently Asked Questions

How tall can a house be in unincorporated St. Tammany Parish?
In the parish's single-family zoning districts, the Unified Development Code caps a house at 35 feet above the natural grade of the lot under Section 400-2.2. That limit applies uniformly across the E Estate, R-1, R-2, L-1, L-2, S-1 and S-2 districts, though E Estate and R-1 also measure against base flood elevation and use whichever figure is higher.
Can a duplex be taller than a single-family house?
Yes. The TF Two-Family Residential District allows structures up to 45 feet under Section 400-2.3(A)(4)(h), 10 feet taller than the 35-foot cap that applies in the single-family districts.
Do apartment buildings have a different height limit near single-family homes?
Yes. M-M and M-H multi-family districts allow 60 feet generally under Section 400-2.4(B)(4)(g) and (C)(4)(g), but any portion of a building within 100 feet of a single-family zoned lot is capped at 35 feet, matching the single-family standard.
What happens if a builder exceeds the height limit?
The Department of Permits and Inspections can reject noncompliant construction documents under Section 300-2(F) or suspend and revoke a permit issued on incorrect information under Section 300-2(J); the applicant can appeal to the Board of Adjustment within 30 days under Section 200-3.10.

Sources & Official References

Other rules in St. Tammany Parish

All St. Tammany Parish rules

Compare St. Tammany Parish to another location·View the Louisiana building setbacks & zoning overview

Get notified when Structure Height Limits in St. Tammany Parish, LA changes

We'll email you the moment we detect a change in the code. No spam, unsubscribe anytime.

We'll never sell or share your email. One-click unsubscribe in every email.

See something wrong?

Help us keep this page accurate. If you notice an error or outdated information, let us know.