Lakewood, CO Building Setbacks & Zoning: Structure Height Limits (2026)
Key Facts
- Primary structure height, R-1 districts
- 35 feet
- Primary structure height, R-MF
- 45 feet
- Accessory structure height
- 20 to 35 feet by district
- Height measured from
- average grade to highest roof point
- Exempt architectural features
- chimneys, spires, elevator penthouses, skylights, more
- Setback for exceeding elements
- 1 ft horizontal per 1 ft over height
Summary
Lakewood, Colorado caps residential building height at 35 feet in every single-family and duplex zone district and 45 feet in the R-MF multifamily district, under Zoning Ordinance Table 17.5.1. Height is measured from average grade to the roof's highest point, and only a defined list of architectural features, like chimneys, spires and elevator penthouses, may exceed the limit.
17.5.1.4: Height Requirements
A. Unless specifically excluded by this Zoning Ordinance, any building or structure, including any accessory building or structure, shall conform to the height requirements applicable to the relevant zone district as set forth in the dimensional standards identified in this Article. ...17.5.2.1: Dimensional Standards All development in residential zone districts must comply with the dimensional standards of Table 17.5.1... Table 17.5.1: Residential Dimensional Standards - Maximum Height (Feet) Primary Structure 35 35 35 35 35 35 45 35 Accessory Structure 35 25 20 20 20 20 20 ...17.5.1.5: Height Measurements A.1. Building and structure height shall be measured from average grade to the coping of a flat roof, the deck line of a mansard roof, the midpoint of the highest gable of a pitched or hipped roof, or the highest point of any other type of roof.
Full Breakdown
Section 17.5.1.4(A) states the baseline rule: "Unless specifically excluded by this Zoning Ordinance, any building or structure, including any accessory building or structure, shall conform to the height requirements applicable to the relevant zone district as set forth in the dimensional standards." Those numbers live in Table 17.5.1 under § 17.5.2.1, which applies "to all development in residential zone districts." For a primary structure, the table sets 35 feet in R-1-43, R-1-18, R-1-12, R-1-9, R-1-6 and R-2, rising to 45 feet in R-MF multifamily and 35 feet in R-MH. Accessory structures top out lower: 35 feet in R-1-43, dropping to 20 feet in the smaller-lot single-family districts.
Height is measured under § 17.5.1.5(A)(1) from "average grade to the coping of a flat roof, the deck line of a mansard roof, the midpoint of the highest gable of a pitched or hipped roof, or the highest point of any other type of roof." Average grade itself is the average of the highest and lowest elevation points along the site's pre-development or improved grade, whichever is more restrictive, per § 17.5.1.5(A)(2)(a).
A defined list of architectural elements, including belfries, bulkheads, chimneys, cupolas, domes, elevator penthouses, flagpoles, skylights, spires, ventilators, and roof-mounted solar or wind equipment, may exceed the district's maximum height under § 17.5.1.4(B), but only to the minimum height needed to accomplish their purpose. Except for spires, belfries, cupolas, domes, flagpoles and chimneys, any such feature must also step back one horizontal foot for every foot it rises above the height limit, § 17.5.1.4(C), and enclosed mechanical equipment or elevator penthouses not serving the roof are capped at 15 feet above the district's allowed height, § 17.5.1.4(D).
Violations & Fines
This Article sets no fixed fine; instead § 17.5.1.4(A) makes any structure exceeding its district's height table nonconforming unless it fits one of the listed architectural exceptions in § 17.5.1.4(B)-(D). The Director may grant additional exceptions "similar to those listed" under § 17.5.1.4(E), but the section builds in no general variance for ordinary over-height construction.
Frequently Asked Questions
How tall can a house be in Lakewood, CO?
Can a chimney or antenna be taller than the height limit in Lakewood?
How is building height measured in Lakewood?
Do accessory structures have a different height limit than the house in Lakewood?
Sources & Official References
Other rules in Lakewood
Compare Lakewood to another location·View the Colorado building setbacks & zoning overview
See something wrong?
Help us keep this page accurate. If you notice an error or outdated information, let us know.
Structure Height Limits in Nearby Cities
How other cities in Jefferson County handle structure height limits.