Skip to main content
CityRuleLookup

Sherman, TX Building Setbacks & Zoning: Structure Height Limits (2026)

Some Restrictions
Compiled from the official code textEditor Martyn O'NeillLast verified October 2026

Key Facts

R-6 and R-5 height
No building shall exceed 35 feet
R-12 height
No building shall exceed 40 feet
R-A and R-E height
No building shall exceed 45 feet
Governing subsection
(4)(C) Height regulations in § 14.02.006 for R-6
Permit step
Site plan with building elevations approved first
Small shed exemption
100 square feet or less and under eight feet tall

Summary

In the City of Sherman, Texas, the height cap is printed in each residential zoning district: no building shall exceed 35 feet in R-6 under Sherman Code of Ordinances § 14.02.006(4)(C), 40 feet in R-12, and 45 feet in R-A and R-E. A site plan with building elevations is reviewed before the permit issues.

(4) Other regulations. ... (C) Height regulations.No building shall exceed 35 feet.

Full Breakdown

The City of Sherman, Texas, sets building height district by district in Chapter 14, as a line in the Other regulations subsection of each residential district. For the R-6 (Single-Family Residential) District, § 14.02.006(4)(C) reads: Height regulations. No building shall exceed 35 feet. The R-5 district in § 14.02.007 prints the same 35 feet.

The larger-lot districts print higher caps. R-12 in § 14.02.005 says no building shall exceed 40 feet. R-A in § 14.02.003 and R-E in § 14.02.004 both say no building shall exceed 45 feet. Each of those districts also prints a minimum floor area for the main building: 1,000 square feet in R-6 and R-A, 1,500 square feet in R-E and R-12, and 800 square feet in R-5.

Height is checked with the site plan. Before a building permit issues for new construction or additions in the R-6 District, a site plan, including building elevations, must be submitted to and approved by the Development Services Director or their designee, using the requirements of § 14.06.004. The elevations are how the height figure gets tested against the 35 foot line.

Accessory structures follow a separate threshold. Under § 14.04.002(b)(7), a portable storage shed is an accessory structure but is not subject to a building permit or the side or rear yard setback requirements if it is less than or equal to 100 square feet in floor area and less than eight (8) feet in height. Accessory buildings are not permitted in the front yard.

A project that cannot meet the cap needs a variance from the board of adjustment, and § 14.06.006 allows one only on a finding of unnecessary hardship that is not self-created and not needed merely to promote economic gain.

Violations & Fines

A building taller than the district cap in the City of Sherman, Texas, violates the zoning ordinance. Section 14.09.003 makes it a class C misdemeanor with a fine of not more than $2,000.00 plus costs, each day a separate offense, and allows a civil penalty of up to $1,000.00 per day. Development Services administers permits, and the board of adjustment decides variances.

Frequently Asked Questions

How tall can a house be in an R-6 district in Sherman, Texas?
Section 14.02.006(4)(C) says no building shall exceed 35 feet in the R-6 (Single-Family Residential) District. The R-5 district prints the same 35 feet. A site plan with building elevations must be approved by the Development Services Director or designee before the building permit issues.
Is the height limit higher in other Sherman districts?
Yes. R-12 prints 40 feet in § 14.02.005, and the R-A and R-E districts print 45 feet in §§ 14.02.003 and 14.02.004. Each district section has its own Height regulations line, so the cap follows the zoning district shown on the Official Zoning Map for the lot.
Does a small backyard shed need a permit in the City of Sherman?
Not if it fits § 14.04.002(b)(7): a portable storage shed that is less than or equal to 100 square feet in floor area and less than eight (8) feet in height is not subject to a building permit or the side or rear yard setback requirements. Larger sheds are accessory structures that follow the full standards.
How do I get relief from a height cap in Sherman?
Apply for a variance to the board of adjustment under § 14.06.006. The board can grant one only if it is not contrary to the public interest, is not needed merely to promote economic gain, and a literal enforcement would cause an unnecessary hardship that is neither self-created nor personal to the owner.

Sources & Official References

Other rules in Sherman

All Sherman rules

Texas rules heatmap·Compare Sherman to another location·View the Texas building setbacks & zoning overview

Get notified when Structure Height Limits in Sherman, TX changes

We'll email you the moment we detect a change in the code. No spam, unsubscribe anytime.

We'll never sell or share your email. One-click unsubscribe in every email.

See something wrong?

Help us keep this page accurate. If you notice an error or outdated information, let us know.