Setback Rules

In the City of Mebane, North Carolina, if half or more lots on a block already sit closer to the street than the district requires, the required front setback becomes the average setback of the two nearest principal buildings, not the district minimum. Landscaping, patios, mailboxes, HVAC equipment, fences, and water-dependent structures may sit inside any required setback, and cornices or bay windows may project two and a half feet, but never closer than three feet to the property line.

Mebane Yard Setback Encroachment Rules

Some Restrictions

Mebane UDO § 4-3(B), (C)

B. Prevailing Front Yard Setback Where fifty percent or more of the lots in a recorded subdivision on the same side of the street as the lot in question are developed with less than the required front yard setbacks, the average setback of the two principal buildings nearest that lot shall be observed as the required minimum setback. ... C. Encroachments into Required Setbacks 1. Encroachments P...

Structure Height Limits

In the City of Mebane, North Carolina, every zoning district in the Unified Development Ordinance carries its own maximum building height in Table 4-2-1, and Section 4-3(A) then lists the narrow set of structures the City lets rise above that limit. Church spires, water towers, silos, and communication masts are exempt outright, while a residential accessory building must still fit the district's height cap or give up extra setback for every foot over 15 feet.

Mebane Building Height Limits And Exemptions

Some Restrictions

Mebane UDO §§ 4-2(B)(5), 4-3(A)

5. Maximum Height (a) The height of all accessory structures and buildings shall comply with maximum height requirements of the zoning district in which located. However, all accessory building setbacks shall increase one foot for every foot in height over 15 feet. ... ... A. Structures Permitted Above Height Limits Except as otherwise prohibited by this Ordinance, the height limitations of thi...

Lot Coverage Limits

In the City of Mebane, North Carolina, properties inside the Highway Corridor Overlay District face a hard impervious-surface ceiling. The Unified Development Ordinance caps total lot coverage by rooftops, paving, walkways and similar surfaces at 70 percent of the lot area, unless the extra stormwater runoff is retained or detained on site. This standard applies only within the designated highway corridors described in Section 3-1(C), not citywide.

Mebane Highway Corridor Overlay Lot Coverage Cap

Some Restrictions

Mebane UDO § 4-7.14(E)(2)(d)

(d) The maximum lot coverage by total impervious surfaces such as rooftops, paving, walkways, etc. shall be 70 percent of the lot area except when stormwater is retained or detained on the site. Any additional runoff resulting from lot coverage in excess of 70 percent must be compensated for by such on-site detention or retention measures.