Building Setbacks & Zoning in Monterey Park, CA (2026)
3 verified building setbacks & zoning rules for Monterey Park, California, sourced directly from the municipal code and official government pages.
Verified from official government sources
Setback Rules
In the City of Monterey Park, Table 21.08(E) sets a uniform 25-foot front and rear yard setback for the R-1, R-2, and R-3 zones, while side yards scale by floor: a 5-foot first-floor side setback everywhere, rising to 10 feet on a second floor, and further out on street-facing sides in the R-2 and R-3 zones.
Monterey Park Residential Yard Setbacks
Some RestrictionsMonterey Park Municipal Code § 21.08.080, Table 21.08(E)
Table 21.08(E) Development Standards in Residential Zones R-1 R-2 R-3 ... Setbacks (ft.) Front setback 25 25 25 Hillside 10 10 10 Side setback, 1st floor 5 5 5 Side setback, 2nd floor 10 10 10 Side setback, facing street, 1st floor 10 15 15 Side setback, facing street, 2nd floor 15 25 25 Rear setback 25 25 25
Structure Height Limits
Houses and other structures in Monterey Park's R-1, R-2 and R-3 zones are capped at two stories and 30 feet, dropping to 15 feet within the required side yard setback area, under the Table 21.08(E) development standards that the City Planner enforces.
Monterey Park Residential Building Height Limit
Some RestrictionsMonterey Park Municipal Code § 21.08.080, Table 21.08(E)
Table 21.08(E) Development Standards in Residential Zones R-1 R-2 R-3 ... Height (ft.) Maximum number building stories 2 2 2 Maximum building height (ft.) 30 30 30 (within side yard setback areas) 15 15 15
Lot Coverage Limits
In the City of Monterey Park, the municipal code defines lot or site coverage as the percentage of a site covered by roofs, soffits, overhangs projecting more than three feet, and decks over four feet high. The clearest numeric cap sits in the Open Space (O-S) zone, which limits total structural coverage to 25% of gross lot area unless the City Council finds a higher figure necessary.
Monterey Park Lot Coverage Limits
Some RestrictionsMonterey Park Municipal Code §§ 21.04.287, 21.07.060(B)
§ 21.04.287. Coverage, Lot or Site. "Lot or site coverage" means the percentage of a site covered by roofs, soffits or overhangs extending more than three feet from a wall, and by decks more than four feet in height. Roofs with openings or perforations 50% or greater of their surface area, pools, or hot tubs shall not be included in lot coverage calculations. ... ... § 21.07.060. Standards of D...
Looking for Los Angeles County county-wide rules?
County ordinances apply to unincorporated areas and may supplement Monterey Park city rules.
Building Setbacks & Zoning in Los Angeles County →