Key Facts

Daytime Limit
50 dBA (7am-10pm)
Nighttime Limit
45 dBA (10pm-7am)
Measured
Within 50 ft of home
Governing Code
County Code Ch. 8.40
Tonal Penalty
Minus 5 dB(A)

Summary

Fresno County's Noise Control ordinance (County Code Chapter 8.40, Ordinance 24-021) caps exterior noise at an affected home at 50 dBA during the day and 45 dBA at night. Data center cooling equipment and backup generators must meet these limits.

City-specific rules exist: Fresno, and Clovis have their own data center noise limits rules that differ from Fresno County's county-level regulations. If you live in one of those cities, check the city-specific page instead.

"Fixed noise source" means a device or a machine which creates sounds while fixed or stationary, including, but not limited to, residential, agricultural, industrial and commercial machinery and equipment, pumps, fans, compressors, air conditioners and refrigeration equipment.

Source: Fresno County Zoning Ordinance & County Code Ch. 8.40 (Noise Control)View official code

Official source re-checked September 7, 2026: no newer edition of the code had been published (publisher’s edition: Code of Ordinances: Supplement 51).

Full Breakdown

Fresno County has no noise rule written for data centers, so a facility's chillers, cooling fans, compressors, and diesel backup generators are held to the countywide Noise Control ordinance in Chapter 8.40 of the County Code, readopted as Ordinance No. 24-021 on December 17, 2024. Section 8.40.040 sets the exterior standard, measured within 50 feet of an affected residence, school, hospital, church, or library: 50 dBA daytime (7 a.m.-10 p.m.) and 45 dBA nighttime (10 p.m.-7 a.m.) for any cumulative 30 minutes in an hour, with higher limits for shorter bursts. The code names air conditioners, fans, compressors, and refrigeration equipment as fixed noise sources, and tonal or recurring impulsive noise is penalized an extra 5 dB(A).

Violations & Fines

Cooling or generator noise exceeding 50 dBA by day or 45 dBA at night at a nearby home violates Chapter 8.40; the Sheriff, Health Officer, or code enforcement can issue citations and require abatement.

Frequently Asked Questions

How loud can a Fresno County data center be?
No more than 50 dBA during the day (7 a.m.-10 p.m.) and 45 dBA at night (10 p.m.-7 a.m.), measured within 50 feet of an affected home under County Code Chapter 8.40.
Are data center backup generators covered for noise?
Yes. Generators, chillers, and compressors are fixed noise sources under Chapter 8.40 and must meet the 50/45 dBA limits at nearby homes. Tonal or pulsing noise is held five decibels lower.

Sources & Official References

Other rules in Fresno County

All Fresno County rules

California rules heatmap·Compare Fresno County to another location·View the California data centers & crypto mining overview

Get notified when Data Center Noise Limits in Fresno County, CA changes

We'll email you the moment we detect a change in the code. No spam, unsubscribe anytime.

We'll never sell or share your email. One-click unsubscribe in every email.

See something wrong?

Help us keep this page accurate. If you notice an error or outdated information, let us know.

Data Center Noise Limits in Cities Across Fresno County