Skip to main content
CityRuleLookup

Rancho Cordova, CA Data Centers & Crypto Mining: Data Center Noise Limits (2026)

Some Restrictions
Compiled from the official code textEditor Martyn O'NeillLast verified July 2026

Key Facts

Code
RCMC Chapter 6.68
Residential limit
55 dBA day / 50 night
Equipment cap
55 dBA at property line
Measured at
Residential property line
Cooling rule
Section 6.68.120

Summary

Rancho Cordova's own noise ordinance, Municipal Code Chapter 6.68, caps exterior noise at a residential property line at 55 dBA daytime (7 a.m.-10 p.m.) and 50 dBA overnight (10 p.m.-7 a.m.). A separate section limits stationary cooling towers, compressors, and fans to 55 dBA at that line.

Equipment installed five years after July 1, 1976, must comply with a maximum limit of 55 dBA at any point at least one foot inside the property line of the affected residential property and three to five feet above ground level.

Source: Rancho Cordova Municipal Code, Title 23 Zoning Code & Chapter 6.68 Noise ControlView official code

Full Breakdown

The city adopted its own Noise Control ordinance, RCMC Chapter 6.68, separate from Sacramento County. Section 6.68.070 sets the exterior standard measured at least one foot inside the affected residential property line: 55 dBA from 7 a.m. to 10 p.m. and 50 dBA from 10 p.m. to 7 a.m. Section 6.68.120 directly targets a data center's mechanical plant - stationary cooling towers, compressors, pumps, fans, and air-conditioning apparatus - capping modern equipment at 55 dBA at the residential property line. Limits drop 5 dBA for pure-tone or impulsive noise. Violations are an infraction after written notice.

Violations & Fines

Noise over the Chapter 6.68 limits is an infraction; a mechanical-equipment violation under Section 6.68.120 carries fines up to $50, $100, then $250 after written notice to correct.

Frequently Asked Questions

How loud can a data center be in Rancho Cordova?
At a residential property line, exterior noise cannot exceed 55 dBA daytime or 50 dBA overnight under RCMC Chapter 6.68. Stationary cooling towers, compressors, and fans are capped at 55 dBA under Section 6.68.120.
Which Rancho Cordova rule covers data-center cooling equipment?
Section 6.68.120 specifically limits stationary cooling towers, compressors, pumps, fans, and air-conditioning to 55 dBA at the affected residential property line - the binding constraint where an industrial site abuts homes.

Sources & Official References

Other rules in Rancho Cordova

All Rancho Cordova rules

California rules heatmap·Compare Rancho Cordova to another location·View the California data centers & crypto mining overview

Get notified when Data Center Noise Limits in Rancho Cordova, CA changes

We'll email you the moment we detect a change in the code. No spam, unsubscribe anytime.

We'll never sell or share your email. One-click unsubscribe in every email.

See something wrong?

Help us keep this page accurate. If you notice an error or outdated information, let us know.

Data Center Noise Limits in Nearby Cities

How other cities in Sacramento County handle data center noise limits.

Sacramento, CA
Some Restrictions
Folsom, CA
Some Restrictions
Citrus Heights, CA
Some Restrictions
Galt, CA
Some Restrictions
Elk Grove, CA
Some Restrictions