Skip to main content
CityRuleLookup

Carroll County, GA Environmental Rules: Flood Elevation Requirements (2026)

Some Restrictions
Compiled from the official code textEditor Martyn O'NeillLast verified September 2026

Key Facts

Freeboard
Lowest floor 2 ft above base flood elevation
Applies to
New construction and substantial improvements
A-zone option
Nonresidential buildings may floodproof instead
Flood vents
1 sq in net area per sq ft enclosed
Permit
Required before construction begins (Sec. 46-33)
Source map
FEMA flood insurance study dated April 19, 2017

Summary

In the special flood hazard areas of unincorporated Carroll County, new construction and substantial improvements must have the lowest floor, including any basement, elevated at least two feet above the base flood elevation shown on the county's FEMA flood insurance study, under Section 46-67 of the county code.

These county ordinances apply to unincorporated areas of Carroll County. Incorporated cities within the county may have their own rules that take precedence over county-level regulations.

(1)Residential construction. New construction and substantial improvement of any residential structure shall have the lowest floor, including the basement, elevated no lower than two feet above the base flood elevation. Should solid foundation perimeter walls be used to elevate a structure, openings sufficient to facilitate the unimpeded movements of floodwaters shall be provided in accordance with standards of subsection (3). ... (2)Nonresidential construction. New construction and substantial improvement of any commercial, industrial, or nonresidential building (or manufactured home) shall have the lowest floor, including the basement, elevated no lower than two feet above the level of the base flood elevation.

Full Breakdown

Carroll County's Flood Damage Prevention ordinance, Chapter 46, Article II, applies inside the special flood hazard areas mapped in the FEMA flood insurance study dated April 19, 2017. Section 46-67(1) requires new construction and substantial improvement of any residential structure to have its lowest floor, including the basement, elevated no lower than two feet above the base flood elevation, one foot above the two-foot minimum FEMA itself requires and commonly called the county's freeboard. If a residence is elevated on solid perimeter walls, the walls need flood vents sized under Section 46-67(3): a minimum of two openings totaling at least one square inch of net area per square foot of enclosed area, with the lowest opening no higher than one foot above grade.

Section 46-67(2) applies the same two-foot freeboard to commercial, industrial and other nonresidential buildings, though those structures may be floodproofed instead of elevated in A zones if a Georgia-licensed engineer or architect certifies the design is watertight and can resist flood loads. A development permit under Section 46-33 is required before any of this construction begins, issued by the county's code and ordinance enforcement officer. These standards govern only the unincorporated county; Carrollton, Villa Rica and the county's other cities administer their own separate floodplain ordinances within their limits.

Violations & Fines

Failing to meet the two-foot freeboard elevation, building without the required development permit, or ignoring conditions attached to a variance is a misdemeanor under Section 46-38, punishable under the general penalty in Section 1-13. Each day the violation continues is a separate offense, and the county magistrate's court has jurisdiction, in addition to any other lawful enforcement action the county may take.

Frequently Asked Questions

How high above the base flood elevation must my house be built?
At least two feet. Section 46-67(1) requires the lowest floor, including any basement, of new or substantially improved residential structures in a special flood hazard area to sit no lower than two feet above the base flood elevation shown on the county's FEMA flood insurance study.
Can a commercial building be floodproofed instead of elevated?
In A zones, yes. Section 46-67(2) allows commercial, industrial or other nonresidential buildings to be floodproofed rather than elevated, but a Georgia-licensed engineer or architect must certify the design is watertight and can resist flood forces before the county will accept it.
Do I need a permit before building in a flood hazard area?
Yes. Section 46-33 requires a development permit before any construction, and Section 46-38 makes building without one, or without meeting the elevation standards, a misdemeanor with each day of noncompliance treated as a separate offense.

Sources & Official References

Other rules in Carroll County

All Carroll County rules

Compare Carroll County to another location·View the Georgia environmental rules overview

Get notified when Flood Elevation Requirements in Carroll County, GA changes

We'll email you the moment we detect a change in the code. No spam, unsubscribe anytime.

We'll never sell or share your email. One-click unsubscribe in every email.

See something wrong?

Help us keep this page accurate. If you notice an error or outdated information, let us know.