Catoosa County, GA Environmental Rules: Flood Elevation Requirements (2026)
Key Facts
- Freeboard requirement
- 2.7 feet above base flood elevation
- Applies to
- New construction and substantial improvements
- No BFE data fallback
- 3 feet above highest adjacent grade
- Manufactured home alt.
- Piers 36 inches above grade
- Certification required
- By registered engineer or land surveyor
- Penalty
- Up to $1,000 fine, 30 days jail
Summary
New construction and substantial improvements in a Catoosa County special flood hazard area must have their lowest floor, including any basement, elevated at least two and seven-tenths feet above the base flood elevation. That 2.7-foot freeboard, set in the county's Flood Damage Prevention ordinance, applies to houses and manufactured homes alike wherever FEMA base flood elevation data exists.
1)New Construction and/or Substantial Improvements. Where base flood elevation data are available, new construction and/or substantial improvement of any structure or manufactured home shall have the lowest floor, including basement, elevated no lower than two and seven-tenths feet above the base flood elevation. Should solid foundation perimeter walls be used to elevate a structure, openings sufficient to facilitate equalization of flood hydrostatic forces on both sides of exterior walls shall be provided in accordance with standards of Section 3.08.04.A(4), "Elevated Buildings."
Full Breakdown
Section 3.08.04.B(1) of the UDC sets the county's core freeboard standard: where base flood elevation data are available, new construction and/or substantial improvement of any structure or manufactured home shall have the lowest floor, including basement, elevated no lower than two and seven-tenths feet above the base flood elevation. All mechanical, electrical, plumbing and HVAC equipment must be elevated to that same 2.7-foot mark. If a builder instead uses solid perimeter foundation walls to raise the structure, Section 3.08.04.A(4) requires flood vents sized to at least one square inch of opening for every square foot of enclosed area below the lowest floor, with the lowest opening no higher than one foot above grade.
Manufactured homes get their own version of the standard under Section 3.08.04.B(3): the lowest floor must clear 2.7 feet above base flood elevation, or the home's chassis must sit on reinforced piers at least 36 inches above grade, whichever is higher, and the home must be anchored against flotation and lateral movement. Where FEMA hasn't published base flood elevation data for a stream, Section 3.08.04.C(3) falls back to a flat three-foot elevation above the highest adjacent grade instead of the 2.7-foot freeboard. In shallow-flooding AO zones, Section 3.08.04.D requires elevation to the flood depth number on the map or, absent a posted number, at least three feet above the highest adjacent grade.
The Stormwater Director certifies and permanently records the as-built lowest-floor elevation for every permit under Section 3.08.03.C(5), and Section 3.08.02.H's $1,000 fine and 30-day jail penalty applies to noncompliance.
Violations & Fines
Failing to build to the 2.7-foot freeboard, or skipping the required as-built elevation certification, is enforced as a Section 3.08.02.H violation: a conviction carries a fine of up to $1,000, up to 30 days in jail, or both, plus prosecution costs, with each day of noncompliance treated as its own offense until the Stormwater Director records a corrected elevation certificate.
Frequently Asked Questions
How high above the flood level must I build in Catoosa County?
What if my creek doesn't have a published base flood elevation?
Who certifies that my house meets the elevation requirement?
Sources & Official References
Other rules in Catoosa County
Compare Catoosa County to another location·View the Georgia environmental rules overview
See something wrong?