Dunwoody, GA Environmental Rules: Flood Elevation Requirements (2026)

Some Restrictions
Compiled from the official code textEditor Martyn O'NeillLast verified September 2026

Key Facts

Freeboard, lowest floor
3 ft above BFE or 1 ft above future elevation
Rule used
Whichever standard is higher
HVAC/electrical equipment
Same freeboard, § 16-140(a)(6)
Adjacent-to-floodplain, residential
3 ft above BFE
Adjacent-to-floodplain, nonresidential
1 ft above BFE (or floodproof)
Manufactured home pier option
36 in. minimum above grade

Summary

New construction in Dunwoody's future-conditions floodplain must have its lowest floor elevated at least three feet above the base flood elevation, or one foot above the future-conditions flood elevation, whichever is higher. Building equipment must clear the same freeboard.

(6)All heating and air conditioning equipment and components (including ductwork), all electrical, ventilation, plumbing, and other service facilities must be designed and/or located at least three feet above the base flood elevation or at least one foot above the future-conditions flood elevation, whichever is higher, so as to prevent water from entering or accumulating within the components during conditions of flooding ... a.New construction. New construction of principal buildings, including manufactured homes is not allowed within the limits of the future-conditions floodplain unless all requirements of section 16-139(c), (d) and (e) have been met. If all of the requirements of section 16-139(c), (d) and (e) have been met, all new construction must have the lowest floor, including basement, elevated at least three feet above the base flood elevation or at least one foot above the future-conditions flood elevation, whichever is higher.

View official code

Official source re-checked September 7, 2026: no newer edition of the code had been published (publisher’s edition: Code of Ordinances: Supplement 49).

Full Breakdown

Section 16-140(a)(6) requires all heating and air conditioning equipment and components including ductwork, plus electrical, ventilation, plumbing and other service facilities, to be designed or located at least three feet above the base flood elevation or one foot above the future-conditions flood elevation, whichever is higher, to keep water from entering or accumulating in them during flooding. Section 16-140(b)(1)a applies the same three-foot-or-one-foot freeboard standard to the lowest floor, including any basement, of new residential construction within the future-conditions floodplain, but only once the no-rise and storage-capacity conditions of section 16-139(c), (d) and (e) have been satisfied; new construction that cannot meet those conditions is barred from the floodplain outright.

Section 16-140(c) extends elevation duties to lots adjacent to, but outside, the floodplain: three feet above base flood elevation for residential buildings and one foot for nonresidential buildings. Nonresidential structures get an alternative under section 16-140(b)(2)a: instead of elevating, they may be floodproofed watertight to one foot above the base flood elevation, or the future-conditions elevation if higher, with a registered engineer or architect certifying the design. Manufactured homes carry their own version of the same freeboard in section 16-140(b)(5), either elevating the lowest floor three feet above base flood elevation or setting the chassis on reinforced piers at least 36 inches above grade.

Violations & Fines

Section 16-136(f) makes any failure to comply with the flood damage prevention division a violation of chapter 16, punishable upon conviction by a fine and/or imprisonment under section 1-6 of the municipal code, with each day the violation continues counted as a separate offense; the city council may also take other lawful action to prevent or remedy a violation. Section 16-141(a)(2) stresses that freeboard variances are meant to be rare, since building below the required elevation raises flood insurance costs and risk, and the zoning board of appeals must find good and sufficient cause, exceptional hardship, and no increase in flood heights before granting one.

Frequently Asked Questions

How high above flood level must I build in Dunwoody's floodplain?
Section 16-140(b)(1)a requires the lowest floor, including any basement, of new residential construction in the future-conditions floodplain to be elevated at least three feet above the base flood elevation or one foot above the future-conditions flood elevation, whichever is higher.
Do my HVAC and electrical systems also need to be elevated?
Yes. Section 16-140(a)(6) requires heating, air conditioning, electrical, ventilation and plumbing equipment to be designed or located at the same three-foot or one-foot freeboard above the applicable flood elevation, so it does not flood even if the structure otherwise meets code.
Can a commercial building floodproof instead of elevating?
Section 16-140(b)(2)a allows nonresidential new construction to be floodproofed watertight to one foot above the base flood elevation instead of elevated, but a registered engineer or architect must certify the design meets accepted standards and submit that certification to the community development director.

Sources & Official References

Other rules in Dunwoody

All Dunwoody rules

Compare Dunwoody to another location·View the Georgia environmental rules overview

Get notified when Flood Elevation Requirements in Dunwoody, GA changes

We'll email you the moment we detect a change in the code. No spam, unsubscribe anytime.

We'll never sell or share your email. One-click unsubscribe in every email.

See something wrong?

Help us keep this page accurate. If you notice an error or outdated information, let us know.