Nashville, TN Environmental Rules: Flood Elevation Requirements (2026)

Some Restrictions
Compiled from the official code textEditor Martyn O'NeillLast verified September 2026

Key Facts

Residential lowest floor
4 ft above BFE
Non-residential lowest floor
1 ft above BFE
Governing chapter
Metro Code Ch. 15.64
Enforcing agency
Dept. of Water & Sewerage Services
Penalty basis
T.C.A. § 68-221-1106, per day

Summary

Metro Nashville requires new structures in the floodplain to elevate the lowest floor at least four feet above base flood elevation for residential use, one foot for non-residential, under Metropolitan Code of Laws Chapter 15.64.

The minimum floor elevation of that portion of any structure intended for human occupancy shall be at least equal to or higher than four feet above the base flood elevation. Those portions of such structures not intended for human occupancy shall be at least equal to or higher than one foot above the base flood elevation. All other related facilities thereto such as electrical equipment, water service, and sanitary sewer connections shall be at least equal to or higher than one foot above the base flood elevation.

View official code

Official source re-checked September 7, 2026: no newer edition of the code had been published (publisher’s edition: Code of Ordinances: Supplement 53 | Charter: Republication 9).

Full Breakdown

Under Metropolitan Code of Laws § 15.64.180, any structure built in a Metro Nashville floodplain after alteration approval must set its lowest floor at least four feet above the base flood elevation if the space is used for human occupancy, or one foot above BFE for non-occupied space and related equipment like electrical, water, and sewer connections. This four-foot standard matches the code's definition of 'flood protection elevation' for residential construction in Section 15.64.010. The director of the Department of Water and Sewerage Services can authorize floodproofing in place of elevation for non-residential structures, per Section 15.64.200, but only as an individual exception, on an engineer's certification.

Violations & Fines

Violations of Chapter 15.64 draw an administrative penalty under T.C.A. § 68-221-1106, with each day of noncompliance counted as a separate violation, plus possible injunctive relief and cost recovery.

Frequently Asked Questions

Does this apply in Belle Meade or the other satellite cities?
No. Belle Meade, Berry Hill, Forest Hills, Goodlettsville, Oak Hill, and Ridgetop keep their own municipal codes and are not governed by Metro's Chapter 15.64 floodplain rules.
Can I floodproof a building instead of elevating it?
Only non-residential structures, and only if the director of Water and Sewerage Services grants an individual exception based on a registered engineer's certification, per § 15.64.180(A)(2).

Sources & Official References

Other rules in Nashville

All Nashville rules

Compare Nashville to another location·View the Tennessee environmental rules overview

Get notified when Flood Elevation Requirements in Nashville, TN changes

We'll email you the moment we detect a change in the code. No spam, unsubscribe anytime.

We'll never sell or share your email. One-click unsubscribe in every email.

See something wrong?

Help us keep this page accurate. If you notice an error or outdated information, let us know.