Key Facts

Default BFE with no data
2 feet above highest adjacent grade
Garage exception size cap
600 sq ft, one story
Group U elevation standard
ASCE 24 design flood elevation
Manufactured home pier height
At least 36 inches above grade
Determining official
City Engineer as Floodplain Administrator

Summary

When a San Bernardino property sits in an approximate Zone A flood hazard area with no FEMA base flood elevation on record, the Floodplain Administrator can set the base flood elevation at two feet above the highest adjacent grade, provided nothing shows flood depths could run deeper. Actual construction elevation requirements then follow from that figure under Chapter 8.79.

Where flood hazard areas are delineated on the FIRM and base flood elevation data have not been provided, the Floodplain Administrator is authorized to... (C) Where base flood elevation and floodway data are not available from another source, where the available data are deemed by the Floodplain Administrator to not reasonably reflect flooding conditions or where the available data are known to be scientifically or technically incorrect or otherwise inadequate: ... (2) Specify that the base flood elevation is two feet above the highest adjacent grade at the location of the development; provided there is no evidence indicating flood depths have been or may be greater than two feet.

View official code

Official source re-checked September 7, 2026: no newer edition of the code had been published (publisher’s edition: 2026 S-2: Supplement contains: Local legislation current through Ord. MC-1666, passed 8-5-2026).

Full Breakdown

270 gives the Floodplain Administrator, the City Engineer, three ways to fill a gap when the FIRM shows a flood hazard area but supplies no base flood elevation data: require the applicant's own engineer-sealed base flood elevation study; obtain or require federal or state base flood elevation and floodway data from another source; or, only when no other data exists or the available data is scientifically inadequate, default to a base flood elevation of two feet above the highest adjacent grade at the development site, so long as nothing shows flood depths could exceed two feet there.

79 ties actual construction to it. 490 only if they are one story, no larger than 600 square feet in a special flood hazard area, anchored against flotation, built with flood damage-resistant materials below the base flood elevation, fitted with code-compliant flood openings, and have their mechanical, plumbing and electrical systems elevated to or above it. 500. 620.

Violations & Fines

Building below the required base flood elevation without qualifying for the detached-garage or Group U exceptions is a violation under Section 8.79.430, treated as a misdemeanor, and a structure lacking documentation of its lowest-floor elevation is presumed noncompliant until the owner submits that documentation. The Floodplain Administrator can issue a stop-work order under Section 8.79.440, and continuing work afterward draws case-by-case penalties, fines and remediation fees from the Public Works Department under Section 8.79.450.

Frequently Asked Questions

How is the base flood elevation set in San Bernardino when FEMA hasn't mapped one?
Section 8.79.270 lets the Floodplain Administrator require an engineer-sealed study, pull federal or state data from another source, or, only if no other data exists or the available data is inadequate, default the base flood elevation to two feet above the highest adjacent grade at the site, provided nothing shows flood depths could exceed two feet.
Can a garage sit below the base flood elevation in San Bernardino?
Yes, but only a detached garage or accessory storage structure that is one story, no larger than 600 square feet in a special flood hazard area, anchored against flotation, built with flood damage-resistant materials, fitted with proper flood openings, and has its utilities elevated to or above the base flood elevation, per Section 8.79.490.
What elevation do manufactured homes need in San Bernardino flood zones?
Section 8.79.610 requires the lowest floor or lowest horizontal structural member of most manufactured homes to sit at or above the base flood elevation, while Section 8.79.620 allows units in certain existing manufactured home parks to instead rest on reinforced piers at least 36 inches above grade.

Sources & Official References

Other rules in San Bernardino

All San Bernardino rules

California rules heatmap·Compare San Bernardino to another location·View the California environmental rules overview

Get notified when Flood Elevation Requirements in San Bernardino, CA changes

We'll email you the moment we detect a change in the code. No spam, unsubscribe anytime.

We'll never sell or share your email. One-click unsubscribe in every email.

See something wrong?

Help us keep this page accurate. If you notice an error or outdated information, let us know.

Flood Elevation Requirements in Nearby Cities

How other cities in San Bernardino County handle flood elevation requirements.

Fontana, CA
Some Restrictions
Chino, CA
Some Restrictions
Rancho Cucamonga, CA
Some Restrictions
Victorville, CA
Some Restrictions
Hesperia, CA
Some Restrictions
Rialto, CA
Some Restrictions
Ontario, CA
Some Restrictions