Merced County, CA Environmental Rules: Flood Elevation Requirements (2026)
Key Facts
- Freeboard, Zone A
- 1 ft above base flood elevation
- Freeboard, Zone AO
- 1 ft above FIRM depth number
- Manufactured homes
- same 1-ft freeboard, anchored foundation
- Certification required
- FEMA Elevation Certificate, twice
- Certifier
- registered engineer/surveyor + Building Inspector
Summary
New homes and substantially improved structures built in a Merced County flood hazard Zone A must set their lowest floor one foot above the base flood elevation, and manufactured homes need the same one-foot freeboard on a permanently anchored foundation. A licensed engineer or surveyor must certify the finished elevation before occupancy.
Residential Construction. New or substantial improvements, shall have the lowest floor, including the basement: (1) In an AO zone, elevated above the highest adjacent grade to a height one foot higher, as required by the California Building Code and ASCE 24, than the depth number specified in feet on the FIRM, or elevated at least two feet above the highest adjacent grade if no depth number is specified. (2) In an A zone, elevated to a height of one foot higher, as required by the California Building Code and ASCE 24, than the base flood elevation, and the base flood elevation shall be determined by one of the methods described in Section 18.26.040(C)(2).
Official source re-checked September 7, 2026: no newer edition of the code had been published (publisher’s edition: rev 4930839; v8 updated 2026-06-02).
Full Breakdown
050(A)(3)(a) sets the freeboard standard for residential construction in the county's mapped flood hazard areas. In an AO zone, the lowest floor, including any basement, must be elevated above the highest adjacent grade to a height one foot higher than the depth number shown on the Flood Insurance Rate Map, or at least two feet above the highest adjacent grade if no depth number is listed. 040(C)(2). In all other flood zones, the lowest floor must sit at or above the base flood elevation itself.
Once construction is finished, a registered professional engineer or surveyor must certify the elevation, and the County Building Inspector verifies the structure was properly elevated. 050(A)(3)(b), but the structure must be watertight below the freeboard elevation and certified by a registered engineer or architect. 050(D)(1), and must be secured to an anchored foundation system to resist collapse and lateral movement. 040(F) requires a FEMA Elevation Certificate to be handed to the floodplain administrator twice: once at the foundation-forms inspection, before concrete is poured, and again once construction is complete, before the county will issue a Certificate of Occupancy.
Violations & Fines
A building or structure in a flood hazard area without documented lowest-floor elevation, required design certifications, or other proof of compliance is presumed to be in violation under § 18.26.030(C)(1) until the paperwork is filed. Occupying a structure before the final FEMA Elevation Certificate is submitted under § 18.26.040(F)(2) can hold up the Certificate of Occupancy, and unpermitted or noncompliant flood-zone construction is a misdemeanor.
Frequently Asked Questions
How much freeboard does Merced County require above base flood elevation?
What about zones where the base flood elevation isn't published, like Zone AO?
When do I need the FEMA Elevation Certificate?
Do manufactured homes get a different standard?