Skip to main content
CityRuleLookup

Warner Robins, GA Environmental Rules: Flood Elevation Requirements (2026)

Significant Restrictions
Compiled from the official code textEditor Martyn O'NeillLast verified September 2026

Key Facts

Freeboard, BFE available
18 inches above base flood elevation
No published BFE data
3 feet above highest adjacent grade
Manufactured home alternative
Piers at least 36 inches above grade
Certification required
By licensed engineer or land surveyor
Missing certification
Stop-work order; presumed violation

Summary

Warner Robins requires new construction and substantially improved structures in mapped flood hazard areas to elevate their lowest floor at least 18 inches above the base flood elevation, a freeboard margin set in Code of Ordinances Sec. 24-425. Streams without published base flood data get a 3-foot-above-grade elevation standard instead.

New construction and/or substantial improvements. Where base flood elevation data are available, new construction and/or substantial improvement of any structure or manufactured home shall have the lowest floor, including basement, elevated no lower than eighteen (18) inches above the base flood elevation. Should solid foundation perimeter walls be used to elevate a structure, openings sufficient to facilitate equalization of flood hydrostatic forces on both sides of exterior walls shall be provided in accordance with standards of subsection (a)(4), "Elevated buildings".

View official code

Official source re-checked September 7, 2026: no newer edition of the code had been published (publisher’s edition: Code of Ordinances: Supplement 69).

Full Breakdown

Sec. 24-425(b)(1) sets the core freeboard standard: where base flood elevation (BFE) data are available, "new construction and/or substantial improvement of any structure or manufactured home shall have the lowest floor, including basement, elevated no lower than eighteen (18) inches above the base flood elevation," and any heating, air conditioning, electrical, ventilation or plumbing equipment must be elevated to that same 18-inch freeboard. Non-residential structures may be floodproofed instead of elevated, but must be watertight to 18 inches above the BFE and certified by a registered professional engineer or architect under Sec.

24-425(b)(2). Manufactured homes get the identical 18-inch lowest-floor standard, or alternatively must sit on reinforced piers at least 36 inches above grade, per Sec. 24-425(b)(3). Where a stream has no published BFE, Sec. 24-425(c)(3) instead requires the lowest floor to sit at least 3 feet above the highest adjacent grade at the building site. In AO shallow-flooding zones, Sec. 24-425(e) requires elevation to the flood depth number shown on the FIRM, or 3 feet above the highest adjacent grade if no depth number is given.

Sec. 24-422 defines "freeboard" as the safety-factor cushion above the calculated flood level that compensates for unknown risks like wave action and urbanization effects, and defines base flood elevation as the elevation shown on the FIRM for a flood with a one-percent annual chance of being equaled or exceeded. Sec. 24-424(b)(2) requires the permit holder to submit an as-built elevation certification, prepared by a professional engineer or licensed land surveyor, immediately after the lowest floor or floodproofing is complete; uncorrected deficiencies or a missing certification triggers a stop-work order.

Violations & Fines

A structure built without the required elevation certificate or other proof of compliance is "presumed to be in violation until such time as that documentation is provided" under the Sec. 24-422 definition of "violation." Failing to submit the as-built certification, or to correct deficiencies the city engineer identifies in it, is cause for the city engineer to issue a stop-work order under Sec. 24-424(b)(2), and any general division violation carries the fine and daily-offense penalty set out in Sec. 24-423(h).

Frequently Asked Questions

How high above the flood level must I build in Warner Robins?
At least 18 inches above the base flood elevation shown on the FIRM for your lot, per Sec. 24-425(b)(1). That freeboard applies to the lowest floor including any basement, and to HVAC, electrical and plumbing equipment serving the structure.
What if my street has no official base flood elevation on file?
Sec. 24-425(c)(3) requires the lowest floor to be at least 3 feet above the highest adjacent grade at the building site when no BFE data exists for the stream, unless a limited detail study sets an 18-inch-above-BFE standard instead.
Do manufactured homes get the same freeboard rule?
Yes, under Sec. 24-425(b)(3) a manufactured home's lowest floor must sit 18 inches above the base flood elevation, or the home can instead be set on reinforced piers at least 36 inches above grade and securely anchored against flotation and lateral movement.

Sources & Official References

Other rules in Warner Robins

All Warner Robins rules

Compare Warner Robins to another location·View the Georgia environmental rules overview

Get notified when Flood Elevation Requirements in Warner Robins, GA changes

We'll email you the moment we detect a change in the code. No spam, unsubscribe anytime.

We'll never sell or share your email. One-click unsubscribe in every email.

See something wrong?

Help us keep this page accurate. If you notice an error or outdated information, let us know.