Fences in unincorporated San Diego County must meet Section 6708 zoning height and location limits and, where a permit applies, the construction standards in County handout PDS-070. Requirements cover footing depth, fire-resistive materials near buildings in WUI areas (Section 707A), and clearances for gates and fire access. Pool barriers and visibility rules add further requirements.
A compliant fence in unincorporated San Diego County must satisfy both zoning and building requirements. Zoning (Section 6708) sets height by location - 42 inches in front/exterior side yards, 72 inches in rear/interior side yards, with rural and administrative exceptions. Gates and gate entry structures may not exceed 12 feet, must sit at least 10 feet from a public road right-of-way or private road easement they access, and must preserve a minimum 13-foot 6-inch vertical clearance for fire-protection vehicles (Section 6708(d) and (e)); the County Fire Code and local fire district ordinances govern gates across fire-access roads. Construction standards from handout PDS-070 require, among other things, posts set in 12-inch-diameter concrete footings extending at least 24 inches into undisturbed natural ground or properly compacted fill, with prescriptive masonry footing and reinforcing tables (Table A). In Wildland-Urban Interface (WUI) areas, any portion of a fence within 5 feet of a building must be non-combustible or approved fire-retardant material meeting Section 707A of the County Building Code. Fences that confine animals must also conform to the Animal Regulations beginning at Section 3000. Swimming-pool enclosure barriers are separately required under the adopted California Building Code/state pool-safety law. Where a fence sits in a required yard, it must not create traffic-visibility hazards, a finding the Director must make when granting fence exceptions under Section 6708(h).
Fences that violate Section 6708 height, location, gate-clearance, or fire-access requirements, or that lack a required building permit, are enforced by PDS Code Compliance and the Building Division. WUI fire-material violations and pool-barrier deficiencies are enforced under the County Building Code, and may require correction or removal.
Other ordinances people look up for this city. Green dot = verified primary-source excerpt.
El Cajon, CA
El Cajon prohibits amplified sound reproduction that disturbs the peace, quiet, or comfort of neighboring residents or businesses. Horn, bell, or mechanical ...
El Cajon, CA
El Cajon addresses barking dogs through general noise provisions and animal control. Animals must be kept so as not to create offensive noise affecting surro...
El Cajon, CA
El Cajon prohibits leaf blower operation between 7 PM and 7 AM within residential zones or 500 feet of them. CA AB 1346 banned the sale of new gas-powered bl...
El Cajon, CA
Industrial and commercial noise in El Cajon is regulated by the zoning performance standards in ECMC Chapter 17.200. Sound levels from any operation or land ...
El Cajon, CA
El Cajon prohibits construction, maintenance, and repair work between 7 PM and 7 AM within residential zones or 500 feet of them. Leaf blowers, mowers, and p...
El Cajon, CA
El Cajon requires paved driveways and off-street parking per ECMC Section 17.245. Off-street parking may not be within 10 feet of a public street, except aut...