Haverford, PA Fire Regulations: Smoke Detectors (2026)

Significant Restrictions
Compiled from the official code textEditor Martyn O'NeillLast verified October 2026

Key Facts

Who must install
The owner of the dwelling
Placement
One per level and one in each bedroom
Power
Primary power or sealed ten-year battery
CO detector
Outside entrance to any bedroom or sleeping area
Multifamily alarm
Monitored system, certified each year
Max fine
$1,000 plus costs

Summary

In Haverford Township, owners of one- and two-family dwellings must install smoke detectors on each level and in each bedroom, powered by the building's primary power or a sealed ten-year battery, plus a carbon monoxide detector outside bedrooms. Multifamily owners add a monitored fire alarm system certified every year.

B. It shall be the responsibility of the owner of new and existing one- and two-family dwellings to install smoke detectors powered by the building's primary power or a nonremovable (sealed) ten-year battery. Smoke detectors must be installed as follows: one on each level of the dwelling and one in each bedroom. In addition to the required smoke detectors, the dwelling must be equipped with a carbon monoxide (CO) detector located outside the entrance to any bedroom or sleeping area. Combination smoke/CO detectors are permitted. C. It shall be the responsibility of the owner of new and existing multiple-family dwellings (buildings containing three or more apartments units) to install smoke detectors and carbon monoxide (CO) detectors in each unit in the same fashion as described for one- and two-family dwellings. ... All fire alarm systems must be inspected, tested, and certified each year by a qualified licensed fire alarm inspector.

Full Breakdown

Section 104-13 of the Haverford Township Code, amended by Ord. No. 2965-2022, puts the detector duty on the owner, not the tenant, for new and existing buildings in Haverford Township, Delaware County.

One- and two-family dwellings come first. Smoke detectors must run on the building's primary power or a nonremovable (sealed) ten-year battery, with one on each level and one in each bedroom. The dwelling also needs a carbon monoxide detector outside the entrance to any bedroom or sleeping area, and combination smoke/CO detectors are permitted.

Multiple-family dwellings, meaning buildings with three or more apartment units, need smoke and CO detectors in each unit in the same fashion. The common areas must carry a monitored fire alarm system made of a fire alarm panel, system smoke detectors, manual pull stations and audible horn/strobe devices. Every fire alarm system must be inspected, tested and certified each year by a qualified licensed fire alarm inspector, and copies of the certification stay on site for Township inspection.

Mixed-use buildings with residential units above nonresidential space follow subsection D: smoke and CO detectors in the residential unit like a one- or two-family home, plus one smoke detector interconnected with the nonresidential unit's smoke detection system.

Related duties in the same section include fire extinguishers placed so no one travels more than 50 feet to reach one, with at least one for each 2,500 square feet of floor area in residential rental properties, and illuminated exit signs in multifamily buildings. The Director of Code Enforcement and the Chief Fire Code Official administer these items, and rental occupancy inspections under § 104-11 check them.

Violations & Fines

Failing to install required detectors or maintain the certified alarm system violates Chapter 104. Under § 104-8, conviction before a District Justice of the Peace brings a fine not exceeding $1,000 plus costs of prosecution, up to 90 days in the county jail if the fine and costs are not paid, and each day in violation is a separate offense. The owner, not the tenant, carries the responsibility.

Frequently Asked Questions

Where must smoke detectors go in a Haverford Township house?
In new and existing one- and two-family dwellings, § 104-13B requires one smoke detector on each level and one in each bedroom, powered by the building's primary power or a nonremovable sealed ten-year battery.
Is a carbon monoxide detector required too?
Yes. The dwelling must have a CO detector outside the entrance to any bedroom or sleeping area, in addition to the smoke detectors. Combination smoke/CO detectors are permitted, so one device can serve both purposes.
Who is responsible for detectors in a Haverford Township apartment?
The owner. For buildings of three or more units, § 104-13C requires the owner to install smoke and CO detectors in each unit and a monitored fire alarm system in the common areas, certified each year by a licensed fire alarm inspector.
What about apartments above a store?
Under § 104-13D, the owner of a mixed-use building must install smoke and CO detectors in the residential unit like a one- or two-family home, plus one smoke detector interconnected with the nonresidential unit's smoke detection system.

Sources & Official References

Other rules in Haverford

All Haverford rules

Compare Haverford to another location·View the Pennsylvania fire regulations overview

Get notified when Smoke Detectors in Haverford, PA changes

We'll email you the moment we detect a change in the code. No spam, unsubscribe anytime.

We'll never sell or share your email. One-click unsubscribe in every email.

See something wrong?

Help us keep this page accurate. If you notice an error or outdated information, let us know.