Summary
Homes built in Grogan's Forest, Shenandoah's PDD 2 planned development in Montgomery County, must install smoke alarms listed and installed to the 2000 International Residential Code and NFPA 72's household fire warning equipment provisions. The requirement sits inside the subdivision's own development criteria in Appendix A, alongside the same section's cross-reference to the city's building code for the rest of home construction.
III.Building code.A.All homes must be designed to the most current edition of the International Residential Code for One and Two Family Dwellings, as adopted and amended by the City of Shenandoah Building Code, section[s] 14-31 through 35 and section[s] 14-71 through 74.B.All homes, once completed, will conform with the provisions set forth in chapter 11 of the International Residential Code 2000 (Energy Efficiency). ... In addition, all smoke alarms shall be listed and installed in accordance with the provisions of the 2000 International Residential Building Code and the household fire warning equipment provisions of NFPA72.
Full Breakdown
Grogan's Forest is PDD 2 of Shenandoah's thirteen planned development districts, and its development criteria for each numbered section, adopted under Ordinance No. O-02-015 and its amendments, sets construction standards on top of whatever the city's general building code otherwise requires. 01, covering the Residential-Patio-SFD (Medium-Low) product built in Section 5 of Grogan's Forest, requires every home to be designed to the current International Residential Code for One and Two Family Dwellings as adopted and amended by the City of Shenandoah Building Code at Sections 14-31 through 14-35 and 14-71 through 14-74, and to meet the energy-efficiency provisions of Chapter 11 of the 2000 International Residential Code.
The same section's structured-wiring addendum for the subdivision then adds, in its own sentence, that all smoke alarms must be listed and installed under the 2000 International Residential Building Code and the household fire warning equipment provisions of NFPA 72. 03, governing the Medium and Medium-High product built in Grogan's Forest Sections 6 and 7, repeat the identical smoke-alarm sentence for those later phases, so the requirement runs across the whole PDD 2 build-out, not just the first section. The requirement layers onto, rather than replaces, the city's own building-permit and inspection process: a third-party qualified inspector, licensed as an architect, registered structural engineer or ICBO/SBCCI-certified building inspector, must sign off at foundation, framing and final inspection before a certificate of occupancy issues.
Violations & Fines
The PDD text itself sets no separate fine for a missing or noncompliant smoke alarm; compliance is enforced through the city's building-permit and certificate-of-occupancy process, since Section 2.01 requires the qualified inspector's foundation, framing and final inspections before occupancy, and a home that does not meet the NFPA 72 and 2000 IRC smoke-alarm provisions is not eligible to pass that final inspection.
Frequently Asked Questions
Does Shenandoah require smoke alarms in every new home?
What standard do Grogan's Forest smoke alarms have to meet?
Who inspects a Grogan's Forest home before it can be occupied?
Does the general Shenandoah building code also require smoke alarms?
Sources & Official References
Other rules in Shenandoah
Texas rules heatmap·Compare Shenandoah to another location·View the Texas fire regulations overview
See something wrong?
Help us keep this page accurate. If you notice an error or outdated information, let us know.
Smoke Detectors in Nearby Cities
How other cities in Montgomery County handle smoke detectors.