Troy, NY Fire Regulations: Smoke Detectors (2026)
Key Facts
- Governing section
- Troy City Code § 176-25
- Required device
- Single-station smoke-detecting alarm on or near the ceiling
- Rental location
- Adjacent to sleeping spaces within rented dwelling units
- Approval
- Underwriters' Laboratories, Inc.
- Power source
- Wired to a lighting circuit, cord-connected, or battery-powered
- Maximum fine
- Not more than $1,000 under § 176-12C
Summary
In the City of Troy, New York, § 176-25 requires at least one single-station smoke-detecting alarm device on or near the ceiling adjacent to sleeping spaces within rented dwelling units, and in sleeping rooms of hotels, motels, lodging houses and dormitory buildings. The device must carry Underwriters' Laboratories approval, and the Director of Code Enforcement enforces the Housing Code.
A. At least one single-station smoke-detecting alarm device, located on or near the ceiling, shall be installed: (1) Adjacent to sleeping spaces within rented dwelling units, and (2) In sleeping rooms for transient occupancies (hotels, motels, lodging houses and dormitory buildings, as herein defined); except that such devices shall not be required for transient occupancies in buildings where: ... D. A single-station smoke-detecting alarm device shall be approved by Underwriters' Laboratories, Inc. ... F. The alarm shall be clearly audible in adjacent sleeping spaces with intervening doors closed. G. Anyone tampering with the devices shall be subject to the penalties imposed under this Code.[1] ... H. The single-station smoke-detecting alarm device may be directly wired into a lighting circuit or be cord-connected to an electrical outlet or be battery-powered.
Full Breakdown
Section 176-25 of the Troy City Code sits in Article IV of Chapter 176, Housing and Property Maintenance, adopted by the Troy City Council. Subsection A requires at least one single-station smoke-detecting alarm device, located on or near the ceiling, adjacent to sleeping spaces within rented dwelling units, and in sleeping rooms for transient occupancies, which the section lists as hotels, motels, lodging houses and dormitory buildings. Transient buildings are excused in three cases only: a total-coverage fire and smoke detecting system required by the Uniform Fire Prevention and Building Code is installed; a total-coverage sprinkler system is installed under that code; or smoke-detecting alarm devices are installed in all corridors, hallways, stairways and other exitways while heat detectors cover furnace rooms, refuse rooms, storage rooms, janitor's closets, lounges, garages, laundry rooms, mechanical rooms, kitchens and cellars adjacent to interior stairways, with activation of any one detector sounding an alarm throughout the entire building.
Subsection B defines the device as an assembly with a photoelectric or ionization type of smoke detector in which the control equipment and audible alarm are in one unit. Subsection D requires approval by Underwriters' Laboratories, Inc. Subsection E requires a design and installation that avoids dead air space, detects smoke and activates the alarm, is reasonably free from false alarm, and gives an indication that the alarm is energized. Subsection F requires the alarm to be clearly audible in adjacent sleeping spaces with intervening doors closed. Subsection H lets the device be directly wired into a lighting circuit, cord-connected to an electrical outlet or battery-powered. Subsection C requires maintenance so that under normal conditions of use the device is not a danger to health and welfare and does not create excessive noise or become a nuisance.
The rule is one piece of the Housing Code's fire-safety package. Section 176-24 bars any person from occupying or letting a dwelling that does not comply with the Uniform Fire Prevention and Building Code and the added safety-from-fire requirements, and § 176-5 gives the Director of Code Enforcement the duty to enforce the chapter.
Violations & Fines
Anyone tampering with a smoke-detecting alarm device is subject to the penalties imposed under the Troy City Code, as § 176-25G states. A violation of any provision of Chapter 176 is a violation under § 176-12C, punishable on conviction by a fine of not more than $1,000 or imprisonment as that subsection provides, or both. The Director of Code Enforcement serves written notice specifying the violation, and an order not promptly complied with can be taken to court.
Frequently Asked Questions
Does a rented apartment in Troy need a smoke alarm?
Can a smoke alarm in a Troy rental run on batteries?
Do hotels and dormitories in Troy need alarms in sleeping rooms?
What is the penalty for tampering with a smoke alarm in Troy?
Sources & Official References
Other rules in Troy
New York rules heatmap·Compare Troy to another location·View the New York fire regulations overview
See something wrong?
Help us keep this page accurate. If you notice an error or outdated information, let us know.