Key Facts
- Freeboard above BFE
- 2 feet
- Elevation with no BFE set
- 2 feet above highest adjacent grade
- Manufactured home chassis threshold
- 36 inches triggers engineering cert
- Enclosed area opening ratio
- 1 sq in per sq ft of enclosed area
- Minimum openings required
- 2, on different sides
Summary
New construction and substantial improvements in Harnett County's mapped flood zones must elevate the reference level to the base flood elevation plus two feet of freeboard, or two feet above the highest adjacent grade where no BFE has been set, under § 153.248 and the § 153.024 definition of regulatory flood protection elevation.
REGULATORY FLOOD PROTECTION ELEVATION (RFPE). The elevation, in relation to mean sea level, to which the reference level of all structures and other development located within special flood hazard areas shall be protected. Where base flood elevations (BFEs) have been determined, this elevation shall be the BFE plus two feet of freeboard. Where no BFE has been established, this elevation shall be at least two feet above the highest adjacent grade.
Official source re-checked September 7, 2026: no newer edition of the code had been published (publisher’s edition: 2025 S-7: Supplement contains: Local legislation current through 11-18-2024; and State Legislation current through 2024 Legislative Service #2).
Full Breakdown
024 defines the Regulatory Flood Protection Elevation (RFPE) as the elevation to which the reference level of structures in special flood hazard areas must be protected: where base flood elevations (BFEs) have been determined, RFPE is the BFE plus two feet of freeboard, and where no BFE has been established, it is at least two feet above the highest adjacent grade. 248(B) applies that standard to new construction and substantial improvement of any residential structure, including manufactured homes, which must have the reference level (including any basement) elevated no lower than the RFPE.
Nonresidential structures must meet the same elevation, or may be floodproofed to the RFPE instead in A, AO, AE, and A1-30 zones if a licensed engineer or architect certifies the structure is watertight and can resist hydrostatic and hydrodynamic loads. New or replacement manufactured homes must have their reference level elevated to the RFPE and be anchored per the state's Regulations for Manufactured/Mobile Homes; if the chassis elevation exceeds 36 inches above grade, an engineering certification is required. Enclosed areas below the RFPE in elevated buildings cannot be used for human habitation, must be built of flood-resistant materials, and in A, AO, AE, and A1-30 zones need at least two openings on different walls sized to one square inch of net opening per square foot of enclosed area, with the bottom of openings no higher than one foot above grade, so hydrostatic pressure equalizes automatically during flooding.
Violations & Fines
New construction below the required RFPE is not compliant, and § 153.247(B) allows the Floodplain Administrator to withhold a certificate of compliance or occupancy or issue a stop-work order until deficiencies are corrected. Chapter 153's general penalty at § 153.999 also applies: civil penalties up to $500, $100-per-day citations after the compliance deadline, and possible misdemeanor prosecution under G.S. § 14-4.
Frequently Asked Questions
How much freeboard above base flood elevation does Harnett County require?
What if my lot has no base flood elevation established?
Can I finish the space below the required flood elevation in Harnett County?
Sources & Official References
Other rules in Harnett County
Compare Harnett County to another location·View the North Carolina hurricane preparedness overview
See something wrong?
Help us keep this page accurate. If you notice an error or outdated information, let us know.