Sumter County, FL Hurricane Preparedness: Flood Elevation (2026)

Some Restrictions
Compiled from the official code textEditor Martyn O'NeillLast verified September 2026

Key Facts

Elevation standard
Base flood elevation plus 1 foot, or design flood elevation
AO Zone standard
Depth number plus 1 foot, minimum 3 feet
Enforcing agency
Sumter County Building Official / Floodplain Administrator
Adopting ordinance
Ord. No. 2013-13, effective August 27, 2013
Variance path
New Sec. 117 flood-hazard variance procedure
General penalty
$500 fine or 60 days jail (§ 1-6)

Summary

In unincorporated Sumter County, new homes in mapped flood hazard areas must have their lowest floor elevated to the base flood elevation plus one foot, or the design flood elevation, whichever is higher, under Sumter County Code § 6-72's amendment to Florida Building Code, Residential R322.2.1. Higher standards apply in Coastal A and AO zones.

These county ordinances apply to unincorporated areas of Sumter County. Incorporated cities within the county may have their own rules that take precedence over county-level regulations.

R322.2.1 Elevation requirements. 1.Buildings and structures in flood hazard areas not designated as Coastal A Zones shall have the lowest floors elevated to or above the base flood elevation plus 1 foot or the design flood elevation, whichever is higher.2.Buildings and structures in flood hazard areas designated as Coastal A Zones shall have the lowest floors elevated to or above the base flood elevation plus 1 foot (305 mm), or to the design flood elevation, whichever is higher.3.In areas of shallow flooding (AO Zones), buildings and structures shall have the lowest floor (including basement) elevated at least as high above the highest adjacent grade as the depth number specified in feet on the FIRM plus 1 foot, or at least 3 feet if a depth number is not specified.4.Basement floors that are below grade on all sides shall be elevated to or above the base flood elevation plus 1 foot or the design flood elevation, whichever is higher. Exception: Enclosed areas below the design flood elevation, including basements whose floors are not below grade on all sides, shall meet the requirements of Section R322.2.2.

Full Breakdown

Sumter County adopted Ordinance No. 1 of the Florida Building Code, Residential, as codified at Sumter County Code § 6-72. The rule sets four elevation standards depending on the flood zone shown on the county's Flood Insurance Rate Map. Outside Coastal A Zones, the lowest floor of a building must sit at or above the base flood elevation plus one foot, or the design flood elevation, whichever is higher. Inside a designated Coastal A Zone, the same one-foot freeboard above base flood elevation, or the design flood elevation, applies.

In AO Zones, where shallow flooding is mapped without a base flood elevation, the lowest floor, including any basement, must clear the highest adjacent grade by the FIRM's depth number plus one foot, or by at least three feet if no depth number is shown. Any basement floor that sits below grade on all sides is held to the same base-flood-elevation-plus-one-foot standard. 2 rather than full elevation. §§ 59-60. 73(5).

Violations & Fines

Sumter County's Building Official reviews and enforces elevation compliance at permitting and inspection; noncompliant plans are rejected and construction below the required elevation cannot receive a certificate of occupancy. Because § 6-72 states no separate penalty, violations of the Florida Building Code amendments fall under the Code's general penalty, Sumter County Code § 1-6: a fine of up to $500, up to 60 days in the county jail, or both, with each day a continuing violation counted as a separate offense.

Frequently Asked Questions

How high must I elevate a new home in a Sumter County flood zone?
Under Sumter County Code § 6-72, amending Florida Building Code Residential R322.2.1, the lowest floor of a new building outside a Coastal A Zone must sit at or above the base flood elevation plus one foot, or the design flood elevation, whichever is higher. In a Coastal A Zone the same one-foot freeboard above base flood elevation applies.
What if my lot is in an AO Zone with shallow flooding?
In AO Zones shown on the FIRM, the lowest floor, including any basement, must be elevated above the highest adjacent grade by the depth number printed on the map plus one foot, or by at least three feet if the map shows no depth number, per § 6-72.
Can I get a variance from the elevation requirement?
Yes. Sumter County added Section 117 to the Florida Building Code, Building, at § 6-71, directing that variance requests for the flood-resistant construction elevations in Section 1612.4 or R322 go through the county's local floodplain management ordinance variance procedure, consistent with F.S. § 553.73(5).

Sources & Official References

Other rules in Sumter County

All Sumter County rules

Florida rules heatmap·Compare Sumter County to another location·View the Florida hurricane preparedness overview

Get notified when Flood Elevation in Sumter County, FL changes

We'll email you the moment we detect a change in the code. No spam, unsubscribe anytime.

We'll never sell or share your email. One-click unsubscribe in every email.

See something wrong?

Help us keep this page accurate. If you notice an error or outdated information, let us know.