Haverford, PA Noise from Specific Sources: HVAC & Mechanical Noise (2026)

Some Restrictions
Compiled from the official code textEditor Martyn O'NeillLast verified October 2026

Key Facts

Covered equipment
Air conditioning units and other mechanical equipment on or near buildings
Daytime hours
7:00 a.m. to 11:00 p.m.
Nighttime hours
11:00 p.m. to 7:00 a.m.
Microphone placement
At least three feet from walls and three feet above floor or ground
Maximum fine
$1,000 plus costs, each day a separate offense
Who approves repairs
Director of Code Enforcement

Summary

In Haverford Township, Delaware County, Pennsylvania, § 117-2 makes it unlawful to run an air conditioning unit or other mechanical equipment attached to or located on premises appurtenant to a building so that it makes excessive noise. Noise counts as excessive when the equipment's sound pressure exceeds the limits in § 117-3, which are set by frequency band and by daytime or nighttime hours.

It shall be unlawful for any person in the operation of an air conditioning unit or units and equipment or other types of mechanical equipment or apparatus installed in or attached to buildings or located on premises appurtenant to buildings to make or produce excessive noise, thereby causing annoyance, inconvenience or detriment to the public or to any other person or persons. Noise shall be considered excessive if the sound pressure from the air-conditioning unit or units and equipment or other type of mechanical equipment or apparatus exceeds the limits hereinafter set forth.

Full Breakdown

Section 117-2 targets the equipment itself: any air conditioning unit or units and equipment or other mechanical equipment or apparatus installed in or attached to a building, or located on premises appurtenant to a building. The operator commits the offense by producing excessive noise that causes annoyance, inconvenience or detriment to the public or to any other person. The code then supplies the test for excessive: sound pressure above the limits in § 117-3, which are numeric and tied to frequency bands.

The chapter splits the day in § 117-1. Daytime hours run from 7:00 a.m. to 11:00 p.m., and nighttime hours run from 11:00 p.m. to 7:00 a.m. The definition of source of complaint points at the neighboring lot: the location on the property adjacent to the complainant's property that holds the air conditioning unit or other mechanical equipment. Readings are taken at the complainant's property line or within the complainant's property.

Under § 117-3C and D, a source heard indoors is measured with the microphone three feet from the nearest window in the room and not less than three feet above the floor, and the inside table applies. A source heard outdoors is measured at the source of the complaint, no closer than three feet to any wall and not less than three feet above the ground, and the outside table applies. Section 117-5 requires a sound-level meter with an octave band analyzer made to American Standards Association standards. If the test finds a violation, § 117-3E orders the operation discontinued until corrections are approved by the Director of Code Enforcement.

Violations & Fines

A violation of Chapter 117 is a summary offense under § 117-7. On conviction before a District Justice of the Peace the fine does not exceed $1,000 plus costs of prosecution, and a violator who does not pay can be sentenced to the county jail for not more than 90 days. Each day the equipment keeps running over the limit is a separate offense. Separately, § 117-3E keeps the unit offline until the Director of Code Enforcement approves the corrections.

Frequently Asked Questions

What hours count as nighttime for air conditioner noise in Haverford Township?
Section 117-1 defines nighttime hours as 11:00 p.m. to 7:00 a.m. and daytime hours as 7:00 a.m. to 11:00 p.m. Section 117-3 has a separate table for each period, and the inside table is lower at night, so a unit heard inside a neighbor's room faces tighter limits after 11:00 p.m.
Where is the noise from a neighbor's unit measured?
Section 117-1 says all measurements are taken at the property line of the complainant or within the complainant's property. For a source heard indoors the microphone sits three feet from the nearest window in that room. For a source heard outdoors it sits at the source of the complaint, no closer than three feet to any wall.
What happens if a unit fails the test?
Under § 117-3E the operation shall be discontinued and not resumed until proper corrections have been made and approved by the Director of Code Enforcement. The owner also faces a fine not exceeding $1,000 plus costs under § 117-7, and each day of violation counts as a separate offense.

Sources & Official References

Other rules in Haverford

All Haverford rules

Compare Haverford to another location·View the Pennsylvania noise from specific sources overview

Get notified when HVAC & Mechanical Noise in Haverford, PA changes

We'll email you the moment we detect a change in the code. No spam, unsubscribe anytime.

We'll never sell or share your email. One-click unsubscribe in every email.

See something wrong?

Help us keep this page accurate. If you notice an error or outdated information, let us know.