El Paso County, CO Outdoor Lighting: Dark Sky Rules (2026)
Key Facts
- Governing section
- LDC Sec. 6.2.3(B)(1)(a)
- Cutoff angle limit
- 90 degrees
- Fixture standard
- full cutoff (IESNA)
- Non-parking-lot cap
- 10 ft pole, 1,800 lumens
Summary
El Paso County requires most outdoor light fixtures to be full cutoff, concealed, and aimed no higher than 90 degrees so light does not spill upward or onto neighbors.
Light fixtures shall be arranged and positioned such that the light sources are concealed and fully shielded so that no direct light or reflection creates a nuisance or hazard to any adjacent ownership or right-of-way and that up-light, spill-light, glare, and unnecessary diffusion are minimized. Light fixtures, except as otherwise permitted herein, are required to be full cutoff as defined by the Illuminating Engineers Society of North America (IESNA). The cut-off angle of an exterior light source shall not exceed 90 degrees.
Official source re-checked September 7, 2026: no newer edition of the code had been published (publisher’s edition: Land Development Code: Supplement 3 | Drainage Criteria Manual: Publication | Engineering Criteria Manual: Supplement 3 | Ordinances: Reformat).
Full Breakdown
Land Development Code Sec. 3(B)(1)(a), 'Concealed or Shielded,' requires light fixtures to be arranged and positioned so the light source is concealed and fully shielded, preventing direct light or reflection from becoming a nuisance or hazard to adjacent ownership or a right-of-way, and minimizing up-light, spill-light, glare, and unnecessary diffusion. Except as otherwise permitted, fixtures must be full cutoff as defined by the Illuminating Engineering Society of North America, and the cutoff angle of an exterior light source cannot exceed 90 degrees; full-cutoff fixtures cannot be tilted or aimed so light distributes above the horizontal plane.
Semi-cutoff or cutoff fixtures are allowed outside parking lots only if pole height stays at or under 10 feet and output stays at or under 1,800 lumens per lamp. The rule is a Chapter 6 development standard applied to lighting plans on site development plan applications; Sec. 3(D) exempts single-family residential lighting from the section except for the separate prohibited-lighting list, so it governs commercial, multifamily, and institutional projects in the unincorporated county.
Violations & Fines
PCD can reject or require revision of a lighting plan that omits full-cutoff fixtures, exceeds a 90-degree cutoff angle, or aims light above the horizontal plane.
Frequently Asked Questions
Does El Paso County require full-cutoff outdoor light fixtures?
Are homeowners' lights covered by this rule?
Sources & Official References
Other rules in El Paso County
Compare El Paso County to another location·View the Colorado outdoor lighting overview
See something wrong?
Help us keep this page accurate. If you notice an error or outdated information, let us know.