Colorado Springs, CO Outdoor Lighting: Dark Sky Rules (2026)

Some Restrictions
Compiled from the official code textEditor Martyn O'NeillLast verified September 2026

Key Facts

Shielding rule
Element hidden from every property line
Full-cutoff limit
≤10% lumens beyond 80° from vertical
HPS lighting
Banned for all site lighting
Efficiency floor
80 lumens per watt minimum
Governing section
City Code § 7.4.1203

Summary

New construction, major expansions, and lighting retrofits in Colorado Springs must meet the dark-sky shielding standards in UDC Part 7.4.12. Fixtures other than motion-detector lights must be fully shielded so the lighting element isn't visible from any property line, and must be full-cutoff type: no more than 10% of emitted lumens beyond 80 degrees from vertical, and no more than 2.5% beyond 90 degrees. High-pressure sodium site lighting is banned outright.

C. Lighting Standards: ... 3. Shielding: a. All lighting fixtures, including wall packs (see figure to the right), except motion detector-activated lighting, shall be fully shielded so that the lighting element is not visible to an observer at any property line, except as stated otherwise in this Part 7.4.12. ... b. Unless otherwise specified, all lighting fixtures shall be full cutoff type as installed. Full cutoff light fixtures are those in which no more than ten (10) percent of emitted lumens can be detected at an angle more than eighty (80) degrees from the vertical axis of the light fixture, and no more than two and a half (2.5) percent of emitted lumens can be detected at an angle more than ninety (90) percent from the vertical axis of the light fixture. ... B. Prohibitions: ... 3. High Pressure Sodium Lights: High pressure sodium lights shall not be used for any type of site lighting.

Source: Colorado Springs Unified Development CodeView official code

Official source re-checked September 7, 2026: no newer edition of the code had been published (publisher’s edition: 2026 S-21: Code current through: Ord. 26-23, passed June 9, 2026).

Full Breakdown

12, Exterior Lighting, which applies to new building construction requiring a Development Plan with on-site lighting, changes of primary use, expansions of gross floor area, dwelling units or parking by 50% or more, and any lighting modification or replacement equal to 50% or more of a parcel's permitted lumens. 3, all lighting fixtures, including wall packs, except motion-detector lighting must be fully shielded so the lighting element can't be seen from any property line. 5 percent at more than 90 degrees. A fixture may beam light upward only if a canopy, roof, or similar structure reflects it back down.

Full shielding is waived for motion-detector lighting under 1,800 lumens that cycles off within 10 minutes, and for underwater pool and fountain lighting. 3 separately bans high-pressure sodium lamps for any site lighting, citywide. 5) and pole-height caps of 20 feet within 75 feet of a residential lot line, so a dark-sky-compliant fixture is judged on output and placement, not shielding alone.

Violations & Fines

Because Part 7.4.12 standards attach to the Development Plan and building-permit process, noncompliant fixtures block plan approval and permit issuance outright rather than triggering a standalone fine. Once installed, unshielded or non-cutoff lighting is unlawful under UDC § 7.1.106 (Conformity With Regulations Required) and can be cited by the City's Code Enforcement Officer for correction.

Frequently Asked Questions

Does every outdoor fixture in Colorado Springs need to be shielded?
Only fixtures triggered by Part 7.4.12's applicability rules: new Development Plans with on-site lighting, use changes, 50%-or-more expansions, or lighting overhauls covering 50% or more of a parcel's lumens. Motion-detector lights under 1,800 lumens and underwater pool lighting are exempt from full shielding.
Can I install a high-pressure sodium light on my property?
No. City Code § 7.4.1203.B.3 bans high-pressure sodium lights for any type of site lighting citywide, regardless of zone district, so replacement fixtures must use another lamp technology that meets the 80-lumens-per-watt efficiency standard and full-cutoff shielding rule.
What counts as a full-cutoff fixture?
One where no more than 10 percent of emitted lumens is detectable beyond 80 degrees from the vertical axis, and no more than 2.5 percent beyond 90 degrees, per City Code § 7.4.1203.C.3.b: effectively no light escaping sideways or upward past the fixture housing.

Sources & Official References

Other rules in Colorado Springs

All Colorado Springs rules

Compare Colorado Springs to another location·View the Colorado outdoor lighting overview

Get notified when Dark Sky Rules in Colorado Springs, CO changes

We'll email you the moment we detect a change in the code. No spam, unsubscribe anytime.

We'll never sell or share your email. One-click unsubscribe in every email.

See something wrong?

Help us keep this page accurate. If you notice an error or outdated information, let us know.